Issues
- Assigned issues: 0
- Reported issues: 12
Projects
- MI/RR IPM (Reporter, Stakeholder, 12/27/2017)
Activity
03/26/2018
- 02:32 PM MI/RR IPM Bug #19502 (New): Excessive delay in first plot, capturing ACNET cursor in window
- I33. Select RR H104. Load spec #10 (or any spec). Save and activate spec. After the spec has completed select "Da...
02/09/2018
- 10:11 AM Elog Idea #18921: There appears to be an auto-gain issue affecting returned data
- I'm seeing the sigma fit to a fixed turn change based on the number of turns collected. Constant turn analyzed, cons...
02/08/2018
- 12:53 PM Elog Idea #18921 (Closed): There appears to be an auto-gain issue affecting returned data
- With a constant MCP voltage I see a factor of 2 decrease in turn 100 between collecting the first 1,000 turns and col...
01/26/2018
- 03:32 PM MI/RR IPM Bug #18773: Single turn plot not showing current data until you toggle single turn -> charge plot -> single turn
- David Slimmer wrote:
> Modified front end code so the Fit Turn is taken from R:4HPMTF instead of the spec when data ...
01/22/2018
- 11:31 AM MI/RR IPM Bug #18773: Single turn plot not showing current data until you toggle single turn -> charge plot -> single turn
- Same behavior on the Z page.
- 10:22 AM MI/RR IPM Bug #18773 (Resolved): Single turn plot not showing current data until you toggle single turn -> charge plot -> single turn
- Taking new data with the plot option of Single Turn shows old data until you toggle from Single Turn to Charge Plot a...
01/19/2018
- 09:25 AM MI/RR IPM Bug #18755 (New): Plotting Charge, Sigma and Turns does not scale to # Turns Analyzed.
- Plotting for Charge, Sigma and Position scales axis for # Turns Acquired when showing plotting # Turns Analyzed. See...
01/05/2018
- 08:57 AM MI/RR IPM Feature #18631: IPM State does not change on I33
- Elliott McCrory wrote:
> This issue has been fixed and is waiting for go-ahead to "mecca --commit" from MI folks.
>... - 08:36 AM MI/RR IPM Feature #18631 (Feedback): IPM State does not change on I33
- Why is this marked resolved? It is still broken. It still reads zero 100% of the time on I33 (it's real reading is ...
12/28/2017
- 11:53 AM MI/RR IPM Feature #18631: IPM State does not change on I33
- Elliott McCrory wrote:
> Is the readback from the state device of the IPM not working? For example, running Spec 11...