Project

General

Profile

Calibration Database

This wiki is intended to detail the calibration database and relevant resources for MicroBooNE.

Contact Persons

  • Brandon Eberly, Wanwei Wu, Ralitsa Sharankova, Wesley R. Ketchum, Maya Wospakrik

Tutorials on Calibration Database

Conditions Database

  • Production: microboone_prod on ifdb05.fnal.gov
  • Development: microboone_dev on ifdb04.fnal.gov
  • Each database is divided into folders.
  • Each folder contains a series of calibration tables ("snapshots") fro a specific type fo calibration data.
  • Each table has a beginning and end time associated with it called the interval of validity (IOV).
  • We use the "Minerva" mode: all rows in a folder have the same IOV.

Database Status

Data Sets (Refer: [[https://microboone-exp.fnal.gov/at_work/AnalysisTools/index.html]])

  • Run 1 open trigger 2 FEM: 3420-3984
  • Run 1 open trigger 3 FEM: 3985-4951
  • Run 1 software trigger: 4952-6998
  • Shutdown 1: 6999-8316
  • Run 2 open trigger: 8317-8405
  • Run 2 before full CRT: 8406-11048
  • Run 2 after full CRT: 11049-11951
  • Shutdown 2: 11952-13696
  • Run 3 before CRT clock fix: 13697-14116
  • Run 3 after CRT clock fix: 14117-17566
  • Run 3 shutdown: 17567-18960
  • Run 4a: 18961-19752

General information (Refer: docdb 4918)

  • MicrobBooNE implementation:
    • SIOVChannelStatusProvider in larevt is our implementa=on of the provider
    • UbooneChannelStatusService in uboonecode is our implementation of the service
    • ChannelStatus provider interface: larevt/CalibrationDBI/Interface/IChannelStatusProvider.h
    • ChannelStatus service interface: larevt/CalibrationDBI/Interface/IChannelStatusService.h
  • Statuses of a wire channel are ordered from "worst" to "best":
    • enum chStatus {kDISCONNECTED=0, kDEAD=1, kLOWNOISE=2, kNOISY=3, kGOOD=4, kUNKNOWN=5}
    • Dead channels = Dead ASICs + Noisy Channels + Chirping Channels(Refer: docdb 6517. In MCC9, this is defined in a different way.)

Channel Status

  1. RUN 2 data:
    1. output area of the results:
      1. Run 8406-11952: /pnfs/uboone/persistent/users/jyoti/RunII_ChStatus/wirecell
  2. RUN 3 data:
    1. output area of the results:
      1. Run 13697-15469: /pnfs/uboone/persistent/users/jyoti/RunIII_ChStatus/wirecell
      2. Run 15470-17055: /pnfs/uboone/persistent/users/jyoti/RunIII_ChStatus_remianing/wirecell
    2. first half: from Oct 27, 2017 (Run 13696) to Mar 16, 2018 (Run 15500) (add tag)
    3. second half (MCC8 tag: v2r1): from Mar 16 (Run 15470) to Jun 8, 2018 (Run 17053)
  3. RUN 3 shutdown data:
    1. Run 17567-18960
      1. output area of the results: /pnfs/uboone/persistent/users/wwu/calibration/channelStatus_run3shutdown
      2. database tag: v3r1
      3. Refer: docdb 21877
  4. RUN 4 data:
    1. Run 18961-19752 (run 4a):
      1. output area of the results: /pnfs/uboone/persistent/users/wwu/calibration/channelStatus_run4a
      2. database tag: v3r0, v3r1
      3. Refer: docdb 21425 and docdb 21428.
    2. Run 19753-23336 (run 4b + 4c +4d):
      1. database tag: v3r2
      2. Refer: docdb 24922

ASIC Settings

  1. Run 3 (run 13697-17055)
    1. Database tags for ASIC misconfiguration (MCC8): v1r2
    2. Results can be found at docdb 19996
  2. Run 3 shutdwon (run 17567-18960) and Run 4 (part: run 18961-20909)
    1. Database tags for ASIC misconfiguration (MCC9): v1r3 (see docdb 22378)
    2. Results can be found at docdb 21883

PMT Gains

  1. Run 1 + Run 3 + Run 3 (most part):
    1. database folder (prod): detpmtgains_data
    2. database tag: v1r0 (see docdb 21428)
    3. Results can be found at docdb 21497

dQ/dx

  1. Run 3 data
    1. Run 15500 - 17055 (Second half part)
      1. Database tags for all YZ, X, T corrections (MCC8): v1r3 (see docdb 22003)
      2. Results can be found at docdb 21904
    2. MCC9 electron lifetime database tag for run 3 (Oct 27, 2017 - Sept 17, 2018): v1r1 (see docdb 24958)
  2. Run 1 data (including Shutdown 1)
    1. Run 4952-8316
      1. Database tags for all YZ correction (MCC9): v2r2 (see docdb 21671)
      2. Database tag for electron lifetime correction (MCC9): v1r0 (see docdb 21428)
  3. MC dQ/dx (MCC9):
    1. Database tags for YZ correction (MCC9): v1r1 (see docdb 21683)