List of systems and components

DAB Test Stand Cluster

sbn-daq01,02,03,04? (private-network hostnames have "-priv" appended)

Annex Room 313

  • sbnd-daq32 : NFS disk volume
    • Has two extra NICs for CRT Bern box readout
  • sbnd-daq33: CAENV1730 ("PMT") readout
    • Contains one CAEN A3818 PCIe card
    • Associated components: pmt01, pmt02, pmt03, pmt04
    • With external triggers: pmtx01, pmtx02, pmtx03, pmtx04
  • sbnd-daq34: ICARUS TPC readout
    • Contains one CAEN A3818 PCIe card
  • sbnd-test02 : Desktop and EPICS development
  • sbnd-test01 : Desktop and access to private network

SBN-FD (ICARUS) detector hall

The network is divided into three segments - Fermilab, DAQ, and DCS/management.
  • Fermi - 131.225.250.0/25 - SBN-FD-Public
  • DAQ - 192.168.191.0/26 - SBN-FD-DAQ-Private - Vlan 2048
  • DCS - 192.168.184.0/23 - SBN-FD-DCS-Private - Vlan 2041

Only two icarus servers at the SBN-FD building are accessible directly from the Fermilab public network - icarus-gateway01 and icarus-gateway02. You must login to one of these two computers to access the other computers on the SBN-FD network.

Central Servers

  • icarus-gateway01, icarus-gateway02 : Path into the ICARUS online computing cluster
    • icarus-gateway01-dcs
    • icarus-gateway02-dcs
  • icarus-db01 : main ICARUS online database
    • icarus-db01-daq
  • icarus-db02 : backup ICARUS online database
    • icarus-db02-daq
  • icarus-nfs01 : backup ICARUS general purpose file server
  • icarus-nfs02 : main ICARUS general purpose file server

Vertical Slice Test Stand

  • icarus-vst01: TPC readout testing
    • icarus-vst01-dcs
  • icarus-vst02: PMT readout testing
    • icarus-vst02-dcs
    • vst02 has been rebooted three times in the last month. There is probably a hardware issue. 11-Nov-2019.

TPC computer servers

  • icarus-tpc01
    • icarus-tpc01-daq
  • icarus-tpc02
    • icarus-tpc02-dcs

PMT computer servers

  • icarus-pmt01

CRT computer servers

  • icarus-crt01
  • icarus-crt02 is still at Wideband, to be moved to FD by the end of 2019 or beginning of 2020
  • icarus-crt03-11 : OS installation ongoing (10/2019)

Naming convention

All computer servers have a Fermilab network connection (131.225.250.0) with dns name icarus-xxxyy.
The systems are divided by functionality. The values of xxx so far are.
  • evb - event builder
  • tpc - TPC readout, A3818 cards installed
  • pmt - PMT readout, A3818 cards installed
  • crt - CRT readout
  • clk - Timing readout
  • dcs - detector control system
  • pdu - power distribution units
  • ipmi - connections to management ports on the computer servers

Wideband

  • icarus-crt02