Front-end information » History » Version 7
« Previous -
Version 7/30
(diff) -
Next » -
Current version
Michael Wallbank, 10/15/2018 12:58 PM
Front-end information¶
V1742 Digitizer¶
Post-Trigger¶
The V1742 has a register named POST_TRIGGER
. This value is a percentage of the readout that is to be after the trigger. There is an implicit latency of around 40 ns, so in reality, the Post-Trigger percentage sets the percentage of the readout that will be after 40 ns past the trigger.
For an unknown reason, only certain values of POST_TRIGGER
are accepted and must be found by trial and error.
Known working values¶
- 0
- 20
- 45
MWPC Controller¶
Details:- Hardware address: 00.80.55.ee.00.01
- IP address (programmed onto board!): 131.225.176.70
- Name: ftbfwc03
- CD system reference number: S22041
- CD equipment ID number: 557912
Log in:
telnet ftbfwc03 <port>Ports (according to here)
- 5000 - daq apps
- 5001 - emergency access
- 5002 - telnet sessions