Below is a running list of commissioning runs.
BEAMLINE DATA

Also see: https://docs.google.com/spreadsheets/d/1kUI1HRDhCQWzimxRcGTcgThaRhS2VXPaaW3TXKHmLLo/edit#gid=0

UP TO DATE AS OF 2019-07-05

Start Date Beamline Run Detector Run Num. files Trigger Pattern Current Notes
2019-05-04 2729 10 WC scintillator panels 1000 A? Run ended with beam off due to klystron issues at Linac, Dig. Freq at 5 GHz
2019-05-05 2730 16 WC scintillator panels 1000 A? Magnet current readout issues begun. Beam downtime at end of run. Dig. Freq at 5 GHz
2019-05-06 2733 4 WC scintillator panels 1000 A? Dig. Freq at 5 GHz
2019-05-06 2734 2 WC scintillator panels 2000 A Test at 2000 A, Dig. Freq at 5 GHz
2019-05-07 2735 7 WC scintillator panels 500 A Test at 500 A (M1 Ref), Dig. Freq at 5 GHz
2019-05-07 2737 11 WCCOINC MWPCOFF SWYDGATE (M=3) 2000 A Run killed after MessageViewer froze, Dig. Freq at 5 GHz
2019-05-08 2749 16 WC1 - WC4 MWPCOFF SWYDGATE 2000 A WC2 had a HV trip. Near the end of the run, TDU RPC returned false error. Dig. Freq at 5 GHz
2019-05-09 2753 2 WC1 - WC4 MWPCOFF SWYDGATE 2000 A First run at 2.5 GHz (all remaining runs at 2.5 too). Run stopped to do controlled access (ECL 610)
2019-05-09 2754 15 WC1 - WC4 MWPCOFF SWYDGATE 2000 A
2019-05-10 2763 3 WCCOINC MWPCOFF SWYDGATE (M=4) 1000 A First of three short runs to test the M-of-4 coincidence logic. (ECL 656)
2019-05-10 2764 3 WCCOINC MWPCOFF SWYDGATE (M=3) 1000 A Second to test M-of-4 coincidence logic
2019-05-10 2765 3 WC1 - WC4 MWPCOFF SWYDGATE 1000 A Last of three runs to test the M-of-4 coincidence logic
2019-05-11 2766 8 WC scintillator panels 1000 A Run ended after beam stopped.
2019-05-20 2776 4 WCCOINC MWPCOFF SWYDGATE (M=4) 1000 A Run ended DQM plots looked weird (probably MWPC noise)
2019-05-20 2778 4 WCCOINC MWPCOFF SWYDGATE (M=4) 1000 A Run ended because DQM crashed
2019-05-20 2779 5 WCCOINC MWPCOFF SWYDGATE (M=4) 1000 A Run ended because test master was being turned off.
2019-05-21 2784 3 TOF1 TOF2 TOF3 TOF4 MWPCOFF SWYDGATE 1000 A For comparison to WC trigger
2019-05-21 2785 16 WC1 WC2 WC3 WC4 MWPCOFF SWYDGATE 1000 A For comparison to WC trigger
2019-05-21 2786 1 WC1 WC2 WC3 WC4 MWPCOFF SWYDGATE 500 A
2019-05-21 2789 1 WC1 WC2 WC3 WC4 MWPCOFF SWYDGATE 500 A
2019-05-22 2791 1 PAD1 PAD2 MWPCOFF SWYDGATE
2019-05-22 2803 5 PAD1 PAD2 PAD4 MWPCOFF SWYDGATE
2019-05-23 2804 9 WCCOINC MWPCOFF SWYDGATE
2019-05-23 2815 1 WCCOINC MWPCOFF SWYDGATE 1500 A
2019-05-23 2817 19 WCCOINC MWPCOFF SWYDGATE 1500 A
2019-05-24 2818 6 WCCOINC MWPCOFF SWYDGATE 2000 A WC trigger, paddle no delay
2019-05-24 2822 7 WCCOINC MWPCOFF SWYDGATE 1000 A WC trigger, paddle no delay
2019-05-25 2824 7 WCCOINC MWPCOFF SWYDGATE 500 A WC trigger, paddle no delay
2019-06-03 2849 3 3/4 WCCOINC SWYDGATE 1000 A
2019-06-03 2850 7 3/4 WCCOINC SWYDGATE 1000 A Run had several beam outages and bizarre networking issues
2019-06-03 2851 1 4/4 SCINT. PADDLES 1000 A Run ended due to low trigger rate
2019-06-03 2852 2 4/4 SCINT. PADDLES 1000 A Run stopped to increase magnet current
2019-06-03 2853 7 4/4 SCINT. PADDLES 1500 A Run stopped to increase magnet current
2019-06-04 2854 6 4/4 SCINT. PADDLES 2000 A
2019-06-04 2855 9 4/4 SCINT. PADDLES 2000 A
2019-06-04 2856 1 PAD1234, 3/4 WCCOINC, FWPULSER 2000 A Killed due to issues getting DQM to run
2019-06-04 2857 3 PAD1234, 3/4 WCCOINC, FWPULSER 2000 A Run stopped to decrease magnet current
2019-06-04 2858 7 PAD1234, 3/4 WCCOINC, FWPULSER 1500 A Run stopped to decrease magnet current
2019-06-05 2859 3 PAD1234, 3/4 WCCOINC, FWPULSER 500 A Run stopped to increase magnet current
2019-06-05 2860 6 PAD1234, 3/4 WCCOINC, FWPULSER 1000 A Run ended to do controlled access to adjust trigger.
2019-06-06 2861 19 PAD1234, 3/4 WCCOINC, FWPULSER 2000 A Trigger gate is 1ms.
2019-06-06 2862 3 PAD1234, 3/4 WCCOINC 2000 A Trigger gate is 1ms. Run stopped to undo the change in trigger gate, back to 10us.
2019-06-06 2863 12 PAD1234, 3/4 WCCOINC 2000 A Shifter was instructed to stop the beam and switch the magnet current off
2019-06-07 2864 1 PAD1234, 3/4 WCCOINC 2000 A
2019-06-07 2867 2 PAD1234, 3/4 WCCOINC 2000 A Stopped to make controlled access to flash TDU-02 firmware and check target WC
2019-06-07 2869 10 PAD1234, 3/4 WCCOINC 2000 A Stopped to change magnet current
2019-06-08 2870 8 PAD1234, 3/4 WCCOINC 500 A End of beam-on week
2019-06-18 2875 3 PAD1234, 3/4 WCCOINC 1000 A Start of beam-on week
2019-06-18 2876 1 PAD1234, 3/4 WCCOINC 1000 A Start of beam-on week
2019-06-18 2877 8 PAD1234, 3/4 WCCOINC 1000 A Stopped for controlled access to work on target wire chamber and TDU-03
2019-06-18 2878 18 PAD1234, 3/4 WCCOINC 1000 A Shorter subruns for beam tuning.
2019-06-18 2879 3 PAD1234, 3/4 WCCOINC 1000 A Back to normal subrun length. Stopped for controlled access
2019-06-18 2880 17 PAD1234, 3/4 WCCOINC 1000 A Stopped for control access.
2019-06-19 2881 1 PAD1234, 3/4 WCCOINC 1000 A Stopped to change file length back to 10 min.
2019-06-19 2882 15 PAD1234, 3/4 WCCOINC 1000 A Stopped to transition to low intensity.
2019-06-19 2883 6 PAD1234, 3/4 WCCOINC 1000 A Low intensity beam.
2019-06-20 2889 10 PAD1234, 3/4 WCCOINC 1735 A Stopped to change beam intensity. Contains some lower intensity beam.
2019-06-20 2890 6 PAD1234, 3/4 WCCOINC 1735 A Low intensity, about 1e8.
2019-06-20 2891 6 PAD1234, 3/4 WCCOINC 1735 A Mostly no beam (MI problems), requested maximum (1e10)
2019-06-20 2892 1 PAD1234, TOFPROMPT/SLOW 1735 A Short run to check TOF trigger, no MWPCs.
2019-06-20 2893 1 PAD1234, 3/4 WCCOINC 990 A 1e10 intensity, but lights were on
2019-06-20 2897 1 PAD1234, 3/4 WCCOINC 992 A 1e10 intensity, 64 GeV secondary
2019-06-20 2898 1 PAD1234, 3/4 WCCOINC 992 A 5e9 intensity, 64 GeV secondary
2019-06-20 2899 100093 1 PAD1234, 3/4 WCCOINC 992 A 5e9 intensity, 64 GeV secondary
2019-06-20 2900 100094 1 PAD1234, 3/4 WCCOINC 992 A 1e9 intensity, 64 GeV secondary
2019-06-20 2901 100095 1 PAD1234, 3/4 WCCOINC 992 A 7.5e8 intensity, 64 GeV secondary
2019-06-20 2902 100096 1 PAD1234, 3/4 WCCOINC 992 A 5e8 intensity, 64 GeV secondary
2019-06-20 2903 100097 1 PAD1234, 3/4 WCCOINC 992 A 2.55e8 intensity, 64 GeV secondary
2019-06-20 2904 100098 1 PAD1234, 3/4 WCCOINC 991 A 1e8 intensity, 64 GeV secondary
2019-06-20 2905 100099 1 PAD1234, 3/4 WCCOINC 991 A 1e8 intensity, 32 GeV secondary
2019-06-21 2906 100100 1 PAD1234, 3/4 WCCOINC 991 A 2.5e8 intensity, 32 GeV secondary
2019-06-21 2907 100101 1 PAD1234, 3/4 WCCOINC 991 A 0-10e8 intensity, 32 GeV secondary
2019-06-21 2908 100102 1 PAD1234, 3/4 WCCOINC 991 A 5e8 intensity, 32 GeV secondary
2019-06-21 2909 100103 1 PAD1234, 3/4 WCCOINC 991 A 7.5e8 intensity, 32 GeV secondary
2019-06-21 2910 100106 1 PAD1234, 3/4 WCCOINC 991 A 10e8 intensity, 32 GeV secondary
2019-06-21 2911 100107 1 PAD1234, 3/4 WCCOINC 991 A 50e8 intensity, 32 GeV secondary
2019-06-21 2935 100133 8 PAD1234, 3/4 WCCOINC 248 A 1e10 intensity, 64 GeV secondary
2019-06-22 2936 100134 1 PAD1234, 3/4 WCCOINC 743 A 1e10 intensity, 64 GeV secondary
2019-06-22 2937 100134 6 PAD1234, 3/4 WCCOINC 743 A 1e10 intensity, 64 GeV secondary
100135
2019-06-22 2938 100135 1 PAD1234, 3/4 WCCOINC 743 A 1e10 intensity, 64 GeV secondary
2019-06-22 2939 100136 7 PAD1234, 3/4 WCCOINC 1238 A 1e10 intensity, 64 GeV secondary
100137
2019-07-01 2961 100168 9 TOFPROMPT 1000 A 1.2e10 intensity, 64 GeV secondary
2019-07-01 2962 100169 2 TOFSLOW 1000 A 0.8e10 intensity, 64 GeV secondary
2019-07-01 2963 100170 7 TOFSLOW 1500 A 0.7e10 intensity, 64 GeV secondary
2019-07-01 2965 1 TOFSLOW 1500 A 80e8 intensity, 64 GeV secondary
2019-07-01 2966 100171 3 WCHDWR 1000 A 113e8 intensity, 64 GeV secondary
2019-07-01 2967 100172 4 TOFUS pre-scaled by 100 1000 A 100-150e8 intensity, 64 GeV secondary, beam off
2019-07-01 2968 100173 1 TOFDS pre-scaled by 100 1000 A 100e8 intensity, 64 GeV secondary
2019-07-01 2969 100174 2 TOFPrompt WCHDWR 1000 A 30-100e8 intensity, 64 GeV secondary
2019-07-01 2970 100175 12 TOFPROMPT || TOFSLOW || WCHDWR || PAD1234 1000 A 110e8 intensity, 64 GeV secondary
2019-07-01 2973 100176 13 TOFPROMPT || TOFSLOW || WCHDWR 1000 A 100e8 intensity, 64 GeV secondary, Det gain scan
100177
2019-07-02 2974 100178 3 TOFPROMPT || TOFSLOW || WCHDWR 1000 A Det gain scan
2019-07-02 2975 100179 3 TOFPROMPT || TOFSLOW || WCHDWR 990 A Det gain scan
2019-07-02 2976 100180 3 TOFPROMPT || TOFSLOW || WCHDWR 991 A Det gain scan
2019-07-02 2978 100183 3 TOFPROMPT || TOFSLOW || WCHDWR 990 A Det gain scan
2019-07-02 2979 100184 24 TOFPROMPT || TOFSLOW || WCHDWR 990 A TDU problems with trigger timestamps maxing out at 1000
100185
2019-07-02 2980 100185 1 TOFPROMPT || TOFSLOW || WCHDWR 1000 A First run with 5ns cable delay added to TOF trigger, trigger board problem
2019-07-02 2981 69 TOFPROMPT || TOFSLOW || WCHDWR 1000 A
2019-07-02 2982 163 TOFPROMPT || TOFSLOW || WCHDWR 1000 A First run with updated TDU board reader buffer depth (1k -> 3k)
2019-07-02 2984 43 TOFPROMPT 1000 A
2019-07-02 2985 12 TOFPROMPT || TOFSLOW 1000 A
2019-07-02 2986 1 WCHWR || PAD1234 992 A Crashed right away
2019-07-02 2987 5 WCHWR || PAD1234 990 A Too many triggers
2019-07-02 2988 3 WCHDWR 990 A
2019-07-02 2989 10 PAD1234 || WCHDWR 1000 A
2019-07-02 2990 1 PAD12 || PAD3 1000 A
2019-07-02 2991 100186 39 PAD23 || PAD14 1000 A
2019-07-02 2992 - 13 PAD23 || PAD14 || TOFPROMPT 1000 A
2019-07-02 2993 - 9 PAD23 || PAD14 || TOFPROMPT || TOFSLOW 1000 A
2019-07-02 2994 - 18 TOFPROMPT || TOFSLOW || WCHDWR 1000 A
2019-07-02 2995 - 1 PAD1 || PAD2 1000 A
2019-07-02 2996 - 11 PAD1 || PAD2 1000 A
2019-07-02 2997 100187 250 TOFPROMPT 1000 A 30-100e8 intensity, 64 GeV secondary
2019-07-02 2998 100188 66 TOFSLOW 991 A 20-55e8 intensity, 64 GeV secondary. Stopped because beam was turning off.
2019-07-03 2999 100191 15 TOFSLOW 1000 A No beam
2019-07-03 3000 14 TOFPROMPT 1000 A Very low trigger rate, low intensity
2019-07-03 3001 100191 78 TOFUS pre-scaled by 10 1000 A Low intensity
100192
2019-07-03 3002 100193 4 TOFUS pre-scaled by 10 1000 A 5-50e8 intensity, Some beam tuning, ended when beamline rack RPS died.
2019-07-03 3004 82 TOFUS pre-scaled by 10 1000 A 50-100e8 intensity, beam tuning, collimator opening 0-21mm
2019-07-03 3005 100193 278 TOFPROMPT 1000 A Beam halo studies, various collimator settings
100194
100195
2019-07-03 3006 100196 106 TOFPROMPT 991 A 0-113e8 intensity, 1.07-1.11 collimator opening
2019-07-03 3007 100197 194 TOFPROMPT 1000 A No beam
2019-07-04 3008 10018 102 TOFPROMPT 1000 A 0-150e8 intensity, 64 GeV secondary, 0.07 collimator opening
2019-07-04 3009 100200 93 TOFPROMPT 1000 A 43-120e8 intensity, 8 GeV secondary, 0.07 collimator opening
2019-07-04 3010 100202 192 TOFPROMPT 1000 A 120e8 intensity, 8 GeV secondary, 1.07 collimator opening
2019-07-04 3011 100203 353 TOFPROMPT 1000 A Beam halo studies, more info here
2019-07-04 3012 100205 142 TOFPROMPT -1000 A 130-153e8 intensity, 64 GeV secondary, 20.6 collimator opening
2019-07-04 3013 100207 122 TOFPROMPT -350 A 40-162e8 intensity, 64 GeV secondary, 20.6 collimator opening
2019-07-04 3014 100208 121 TOFPROMPT -500 A 130-160e8 intensity, 64 GeV secondary, 20.6 collimator opening
2019-07-04 3015 100209 120 TOFPROMPT -750 A 130e8 intensity, 64 GeV secondary, 20.6 collimator opening
2019-07-05 3023 100210 96 TOFPROMPT -1250 A 120-130e8 intensity, 64 GeV secondary, 20.6 collimator opening, no MWPC triggers
2019-07-05 3024 100211 122 TOFPROMPT -1500 A 120-140e8 intensity, 64 GeV secondary, 20.6 collimator opening, no MWPC or TDU triggers
2019-07-05 3025 100212 64 TOFPROMPT -1750 A 80-150e8 intensity, 64 GeV secondary, no MWPC triggers
2019-07-05 3026 125 TOFPROMPT -1730 A 150e8 intensity, 64 GeV secondary
2019-07-05 3027 100212 413 TOFSLOW 1000 A 150e8 intensity, 64 GeV secondary, beam tuning throughout
100213
100214
100215
100216
2019-07-05 3028 100217 84 TOFSLOW 1000 A 10e8 intensity, 64 GeV secondary, 1 spill every 2 minutes (MI LCW high temps), MC6Q4,5,6 set to 0
2019-07-05 3029 100218 650 TOFSLOW 1000 A Started with 10e8 intensity, 1 spill every 2 minutes (MI LCW high temps), MC6Q4,5,6 set to nominal last beam before shutdown
2019-12-09 3074 100249 8 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A dcm-5-01-01 crashed, new run started
2019-12-09 3074 100250 10 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A Event display not updating properly, new run started
2019-12-09 3074 100251 15 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A run crashed with dcm Ctr Reg errors. new run started
2019-12-09 3075 100252 current on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A Det. runs 100252 - 3 both had to be ended due to DDT Activity trigger dying and the beamline trigger EVD going funky
100253
100254
2019-12-10 3075 100254 24 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 997 A intentionally stopped, due to DDT Activity trigger dying
2019-12-10 3075 100255 28 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 997 A intentionally stopped, due to change of MCenter beam intensity
2019-12-10 3076 100256 11 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 997 A Higher beam intensity, was stopped, due to DDT Activity trigger dying
2019-12-10 3076 100257 9 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 997 A Higher beam intensity, stopped, due to DDT Activity trigger dying
2019-12-10 3077 100258 1 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A BeamLine Run 3077 kept crashing because of the wire chamber issues
2019-12-10 3078 100258 1 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A BeamLine Run 3077 kept crashing because of the wire chamber issues. Detector Run 100258 crashed (dcm-5-01-02 alarm)
2019-12-10 3080 100259 14 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A DataLogger crashed. Run 100260 started.
100260 Stopped because of low DDT Activity trigger
100261 Stopped because of low DDT Activity trigger
100262 Stopped because of low DDT ACtivity trigger
2019-12-11 3080 100263 36 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 +991 A stopped upon cooling Water temp. alarm
2019-12-11 N/A 100265 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A No beam, no beamline DAQ, running cosmic data
2019-12-11 N/A 100263 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A Still no beam + DDT triggers turned off to see what happens after ~2 hrs of running
2019-12-11 3082 100267 1 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A stopped to fix wire chamber error
2019-12-11 3083 100267 6 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A chiller tripped ending det. run
100268 DDT slowly died again so restarted the run
100269
2019-12-12 3083 10269 5-24 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A OK, until DDT Activity drop
2019-12-12 3083 10270 26 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A OK, until DDT Activity drop
2019-12-12 3083 10271 25 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A until DDT Activity drop, followed by total RC crash, due to water chiller valve issue
2019-12-12 3084 none 0 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A after Beam stopped at 7 am, beamline DAQ continued until 9am
2019-12-12 N/A 100272 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A Detector DAQ run started after water chiller valve is back
2019-12-12 N/A 100273 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A Detector DAQ restarted using DAQ R14 instead of R16 to try to mitigate DDT Activity trigger issue
2019-12-12 N/A 100274 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 0 A Previous run stopped. Teresa did a DSO scan, modified some threshold, changed DAQ release back to R16 (DDT Activity trigger was still dropping after ~2 hrs of running).
2019-12-12 3085 100274 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A Beam is back, run crashed
2019-12-12 3086 100274 N/A on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A
2019-12-12 3089 100274 10 on: WCCOINC MWPCOFF SWYDGATE off: DIGBUSY with the WC coincidence on 3 out of 4 991 A no beam for parts of files 3,4,9,and 10. det. run ended for ddt trigger failure again
100275 ddt trigger failure
100276
2019-12-16 3128 100309 N/A on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991 A Restarted detector and beamline DAQ after the "Load Run Config" issue (some resources were selected that should not have been)
2019-12-16 3128 100310 11 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991 A Restarted RC after a crash (multiple DCM error messages)
2019-12-16 3128 100311 11 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991 A
2019-12-16 3129 100311 1 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restart for recovering ARTDAQMsgViewer
2019-12-16 3130 100311 1 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restart for recovering ARTDAQMsgViewer
2019-12-16 3131 100311 1 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restart for recovering ARTDAQMsgViewer
2019-12-16 3132 100312 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Detector DAQ rolled back to R14
2019-12-17 3132 100314 13 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-17 3132 100315 15 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Beamline DAQ stopped - no beam
2019-12-17 N/A 100315 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0 A No beam: taking cosmic data, run stopped for hall access
2019-12-17 N/A 100316 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0 A Running...
2019-12-17 3133 100318 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Beamline DAQ stalled
2019-12-17 3134 100318 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Detector DAQ crash
2019-12-17 3134 100319 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Beam off for about 20mins
2019-12-17 3134 100320 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Running...
2019-12-18 3134 100321 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-18 3134 100321 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-18 3134 100322 12 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-18 3134 100323 14 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of a DCM crash
2019-12-18 3136 100324 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Beamline DAQ restarted (DQM issues)
2019-12-18 3137 100324 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-18 3138-3142 100325 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Short beamline DAQ runs, Mike was fiddling with the DAQ
2019-12-18 3143 100325 ??? on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Running...
2019-12-19 3143 100329 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-19 3143 100330 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-19 3143 100331 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-19 3143 100332 18 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A RC crashed, DDS needed to be restarted
2019-12-19 3143 100333 21 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-19 3143 100334 24 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-19 3143 100335 ??? on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Running...
2019-12-20 3144 100338 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-20 3144 100339 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-20 3144 100340 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-20 3144 100341 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-20 3144 100342 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate, beam line stopped for monitoring updates
2019-12-20 3145 100342 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A beam line stopped for monitoring updates
2019-12-20 3145 100343 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Detector DAQ stopped for a monitoring update
2019-12-20 3146 100344 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A beam line stopped for monitoring updates
2019-12-21 3149 100347 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restarting Beamline DAQ: DQM crashed
2019-12-21 3150 100347 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restarting Beamline DAQ: DQM crashed
2019-12-21 3151 100347 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restarting Beamline DAQ: DQM crashed
2019-12-21 3152 100347 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-21 3152 100348 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-21 3152 100349 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-21 3152 100350 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-21 3152 100351 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-22 3154 100355 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Detector crash, Run control: Killing Partition and starting a new Run
2019-12-22 3154 100356 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-22 3154 100357 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-22 3154 100358 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restarting Beamline DAQ: DQM crashed
2019-12-22 3155 100358 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Restarting Beamline DAQ: DQM crashed (did not work with the first restart)
2019-12-22 3156 100359 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-22 3156 100360 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-23 3160 100366 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-23 3160 100367 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-24 No Beam 100371 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0 Stopped because of crash in Event display (Beam triggers, probably because there is no Beam)
2019-12-24 No Beam 100373 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0 Stopped because of crash in Spill Server(That was not necessary. Restarting the spill server fixed the problem )
2019-12-25 3164 100377 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-25 3164 100378 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-26 3166 100382 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of low DDT Activity rate
2019-12-26 3166 100383 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991 A Stopped because of Control run crash
2019-12-27 3167 100388 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0 A Stopped Beamline DAQ because we do not have beam
2019-12-27 No beam 100389 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0A Stopped detector DAQ, DAQ trigger disappeared and crash Run Control
2019-12-30 No beam 100396 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0A No Beam
2019-12-31 No beam 100402 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 0A No Beam
2019-12-31 3176 100403 N/A on: internal timing mode 991A Started because the beam turned back on.
2019-12-31 3177 100403 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Beam run restarted with the trigger condition corrected
2019-12-31 3178 100403 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Trying to get the run restarted
2019-12-31 3179 100403 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Trying to get the run restarted
2019-12-31 3180 100403 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Trying to get the run restarted
2019-12-31 3181 100404 N/A on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Steady beam line run, restarted after detector crash
2020-1-1 3182 100405 2 on: TOFDS1 TRIGCLEAR SWYDGATE off: DIGBUSY 991A Steady until power glitch at AD brought the beam down for the day
2020-1-3 3207 100419 5 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991A Steady until DQM Terminal stopped updating.
2020-1-4 3208 100421 5 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991A Beamline DAQ Threw error and restarted the new Run 3208.
2020-1-4 3209 100424 7 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991A Beamline was down around 20 minutes during shift.
2020-1-5 3209 100429 18 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991A Beamline DAQ terminal showed error, so we started a new run.
2020-1-5 3210 100430 8 on: TOFDS1 MWPCOFF SWYDGATE off: DIGBUSY 991A Steady Beamline throughout shift.

DETECTOR DATA

Using this as a dumping ground for runs that, on the other detectors, would be added to the Manual Bad Runs list. We don't really have a mechanism in place yet for excluding certain runs, but the following should not be used for anything, including calibration.

Detector Run Reason to exclude
100490 Warm run for FEB firmware tests
100491 Warm run for FEB firmware tests
100492 Warm run for FEB firmware tests
100498 Warm run for FEB firmware tests
100499 Warm run for FEB firmware tests