Commissioning Runs » History » Version 3
« Previous -
Version 3/246
(diff) -
Next » -
Current version
Varun Raj, 05/10/2019 09:46 PM
Commissioning runs¶
Below is a running list of commissioning runs.
UP TO DATE AS OF 2019-05-10¶
Start Date | Run | Num. files | Trigger Pattern | Current | Dig. Freq. |Notes -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-04 | 2729 | 10 | WC scintillator panels | 1000 A? | 5 GHz | Run ended with beam off due to klystron | | | off: DIGBUSY | | | issues at Linac. -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-05 | 2730 | 16 | WC scintillator panels | 1000 A? | 5 GHz | Magnet current readout issues begun. Beam | | | off: DIGBUSY | | | downtime at end of run. -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-06 | 2733 | 4 | WC scintillator panels | 1000 A? | 5 GHz | | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-06 | 2734 | 2 | WC scintillator panels | 2000 A | 5 GHz | Test at 2000 A | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-07 | 2735 | 7 | WC scintillator panels | 500 A | 5 GHz | Test at 500 A (M1 Ref) | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-07 | 2737 | 11 | WCCOINC MWPCOFF SWYDGATE (M=3) | 2000 A | 5 GHz | Run killed after MessageViewer froze | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-08 | 2749 | 16 | WC1 - WC4 MWPCOFF SWYDGATE | 2000 A | 5 GHz | WC2 had a HV trip. Near the end of the run, | | | off: DIGBUSY | | | TDU RPC returned false error. -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-09 | 2753 | 2 | WC1 - WC4 MWPCOFF SWYDGATE | 2000 A | 2.5 GHz | First run at 2.5 GHz. Run stopped to do | | | off: DIGBUSY | | | controlled access (ECL @610) -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-09 | 2754 | 15 | WC1 - WC4 MWPCOFF SWYDGATE | 2000 A | 2.5 GHz | | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-10 | 2763 | 3 | WCCOINC MWPCOFF SWYDGATE (M=4) | 1000 A | 2.5 GHz | First of three short runs to test the | | | off: DIGBUSY | | | M-of-4 coincidence logic. (ECL @656) -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-10 | 2764 | 3 | WCCOINC MWPCOFF SWYDGATE (M=3) | 1000 A | 2.5 GHz | Second to test M-of-4 coincidence logic | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-10 | 2765 | 3 | WC1 - WC4 MWPCOFF SWYDGATE | 1000 A | 2.5 GHz | Last of three runs to test the M-of-4 | | | off: DIGBUSY | | | coincidence logic -----------+-------+------------+--------------------------------+---------+------------+--------------------------------------------- 2019-05-11 | 2766 | ?? | WC scintillator panels | 1000 A | 2.5 GHz | | | | off: DIGBUSY | | | -----------+-------+------------+--------------------------------+---------+------------+---------------------------------------------