h1. Running DAQInterface
2 1 John Freeman
3 37 John Freeman
DAQInterface is designed to be run, along with rest of the run control code, on lbne35t-gateway01.fnal.gov, using the lbnedaq account, or on lbnedaqtest01.fnal.gov using one's personal account. For use on lbnedaqtest01, please contact John Freeman at jcfree@fnal.gov; these instructions will focus the use of DAQInterface on the gateway node.  The code is located at /data/lbnedaq/scratch/DAQInterface/lbnerc. To get started, first setup the environment:
4 1 John Freeman
5 30 John Freeman
<pre>
6 30 John Freeman
cd /data/lbnedaq/scratch/DAQInterface
7 30 John Freeman
source fireup
8 30 John Freeman
</pre>
9 1 John Freeman
10 30 John Freeman
This will take you into the /data/lbnedaq/scratch/DAQInterface/lbnerc directory. It's a good idea to check whether lbnecontrol (the run control application) and/or DAQInterface (the component which intermediates between run control and artdaq processes) are already running; if they are, the instructions below won't work. To check this, you can try:
11 1 John Freeman
12 30 John Freeman
<pre>
13 33 John Freeman
ps aux | grep -v grep | grep lbnecontrol
14 33 John Freeman
ps aux | grep -v grep | grep daqinterface
15 30 John Freeman
</pre>
16 1 John Freeman
17 33 John Freeman
If these processes are running, it either means that someone else is using DAQInterface, or that someone else who's done with DAQInterface forgot to clean up. As the 9th and 10th fields of the row of variables "ps aux" returns concern how long the program has been running, you can use these values as well as your best judgement, then, before deciding these processes are not in active use and killing them. 
18 1 John Freeman
19 30 John Freeman
Assuming the processes aren't running, before getting started, take a look at the configuration file, found in docs/config.txt (relative to /data/lbnedaq/scratch/DAQInterface/lbnerc). It should look something like the following:
20 1 John Freeman
21 1 John Freeman
<pre>
22 30 John Freeman
23 30 John Freeman
lbne-artdaq: /data/lbnedaq/rce/build_lbne-artdaq
24 30 John Freeman
25 30 John Freeman
PMT host: lbnedaq3
26 30 John Freeman
27 30 John Freeman
log directory:   /data/lbnedaq/daqlogs
28 30 John Freeman
29 34 John Freeman
pause before initialization: 0
30 34 John Freeman
31 34 John Freeman
debug level: 1
32 34 John Freeman
33 30 John Freeman
BoardReader host: lbnedaq2
34 30 John Freeman
BoardReader port: 5205
35 30 John Freeman
BoardReader fhicl: /data/lbnedaq/fcl/BoardReader_TPC_lbnedaq2_1.fcl
36 30 John Freeman
37 30 John Freeman
BoardReader host: lbnedaq2
38 30 John Freeman
BoardReader port: 5206
39 30 John Freeman
BoardReader fhicl: /data/lbnedaq/fcl/BoardReader_TPC_lbnedaq2_2.fcl
40 30 John Freeman
41 30 John Freeman
EventBuilder host: lbnedaq3
42 30 John Freeman
EventBuilder port: 5235
43 30 John Freeman
EventBuilder fhicl: /data/lbnedaq/fcl/EventBuilder_lbnedaq2_1.fcl
44 30 John Freeman
45 30 John Freeman
EventBuilder host: lbnedaq3
46 30 John Freeman
EventBuilder port: 5236
47 30 John Freeman
EventBuilder fhicl: /data/lbnedaq/fcl/EventBuilder_lbnedaq2_2.fcl
48 30 John Freeman
49 30 John Freeman
Aggregator host: lbnedaq2
50 30 John Freeman
Aggregator port: 5265
51 30 John Freeman
Aggregator fhicl: /data/lbnedaq/fcl/Aggregator_lbnedaq2_1.fcl
52 30 John Freeman
53 30 John Freeman
Aggregator host: lbnedaq2
54 30 John Freeman
Aggregator port: 5266
55 30 John Freeman
Aggregator fhicl: /data/lbnedaq/fcl/Aggregator_lbnedaq2_2.fcl
56 1 John Freeman
57 30 John Freeman
</pre>
58 1 John Freeman
59 39 John Freeman
The "lbne-artdaq" parameter allows the user to set the directory in which the desired build of lbne-artdaq to use is located, the "PMT host" parameter is the host on which artdaq's process management tool script (pmt.rb, used by DAQInterface to launch and kill the artdaq processes) will run, and "log directory" is the directory to which lbne-artdaq's output will be sent. The "debug level" parameter allows the user to set the verbosity level of the output to the screen; setting it to higher values creates greater verbosity, and as a practical matter, the range of settings is currently 0-3. Loosely speaking, "0" means minimal output (not much beyond simply announcing a transition is complete), "1" includes announcements of progress during transitions, "2" includes these announcements plus the values of certain variables as well as lbne-artdaq output, and "3" is primarily of developer interest. The "pause before initialization" parameter allows the user to set a pause, in seconds, between when the artdaq processes start and when they're initialized; it has been observed that a latency of a few seconds is needed for initialization to proceed correctly (though this is not always the case -- on lbne35t-gateway01, with a high setting for "debug level", a pause is not needed; the reason why "debug level" matters in this context is not yet understood).
60 1 John Freeman
61 40 John Freeman
After these individual parameters, every cluster of three lines allows one to define an artdaq process; each line should either contain "BoardReader", "EventBuilder" or "Aggregator", defining the process type, and every cluster of three lines should have the same process type. The three lines let one define the host and port of the artdaq process (to run an artdaq process on the same host as you're on, use "localhost"), as well as the FHiCL document which will be used to initialize it. Best practice is to place those FHiCL documents in the /data/lbnedaq/fcl directory. Please note that the order of processes matters, and that they should be listed front-end to back-end, i.e., BoardReader definitions should appear before EventBuilders should appear before Aggregators. 
62 1 John Freeman
63 36 John Freeman
As of this writing (10/1/14) in the repo there currently exist versions of the config.txt file designed to run under different configurations; docs/config_lbnedaqtest01.txt runs simulated data on lbnedaqtest01, docs/config_lbne35t-gateway01.txt runs simulated data on lbne35t-gateway01, and docs/config_lbne35t-gateway01_RCE.txt runs RCEs on lbne35t-gateway01. If you wish to use a particular configuration, copy it into config.txt and then make any appropriate tweaks. 
64 36 John Freeman
65 30 John Freeman
Once you have the configuration file written to your specifications, you can then start run control and DAQInterface:
66 30 John Freeman
67 30 John Freeman
<pre>
68 30 John Freeman
lbnecontrol &
69 27 John Freeman
daqinterface -n daqint -r 5570 -c localhost -H localhost &
70 30 John Freeman
</pre>
71 30 John Freeman
72 1 John Freeman
Here, the "daqint" argument is arbitrary, and is the name you'll give the DAQInterface process; the "5570" argument is the port off of which DAQInterface will run. 
73 1 John Freeman
74 34 John Freeman
Now, you can take DAQ Interface through the standard transitions. At all stages, you can use the "lbnecmd check" command to see what state DAQInterface is in; note that you'll want to wait for a transition to complete before issuing another one, otherwise you'll receive a warning and the transition request will be ignored. Without using "lbnecmd check" you can also just look for a message like the following to know that a given transition has completed:
75 34 John Freeman
76 34 John Freeman
<pre>
77 34 John Freeman
Initialize transition complete; if running DAQInterface in the background, can press <enter> to return to shell prompt
78 34 John Freeman
</pre>
79 30 John Freeman
80 38 John Freeman
Note that if a high "debug level" has been set, this message can get buried in a set of output messages; in this case "lbnecmd check" may be the easiest way to determine what state the system is in. 
81 38 John Freeman
82 30 John Freeman
First, take DAQInterface from the "stopped" to the "ready" state; this will create the artdaq processes on the hosts you specified, and initialize them with the FHiCL documents you specified:
83 29 John Freeman
<pre>
84 30 John Freeman
lbnecmd init daq
85 29 John Freeman
</pre>
86 30 John Freeman
87 30 John Freeman
Take DAQInterface from the "ready" to the "running" state, in order to begin datataking:
88 29 John Freeman
<pre>
89 30 John Freeman
lbnecmd start daq
90 38 John Freeman
</pre>
91 38 John Freeman
92 38 John Freeman
Pause the running of the DAQ, putting DAQInterface into the "paused" state:
93 38 John Freeman
<pre>
94 38 John Freeman
lbnecmd pause daq
95 38 John Freeman
</pre>
96 38 John Freeman
97 38 John Freeman
Resume the running of the DAQ, putting returning to the "running" state:
98 38 John Freeman
<pre>
99 38 John Freeman
lbnecmd resume daq
100 29 John Freeman
</pre>
101 30 John Freeman
102 30 John Freeman
Halt the running of the DAQ, returning DAQInterface to the "ready" state from the "running" state:
103 29 John Freeman
<pre>
104 29 John Freeman
lbnecmd stop daq
105 29 John Freeman
</pre>
106 30 John Freeman
107 30 John Freeman
Now, return to the "stopped" state, killing all the artdaq processes:
108 29 John Freeman
<pre>
109 29 John Freeman
lbnecmd terminate daq
110 22 John Freeman
</pre>
111 21 John Freeman
112 1 John Freeman
113 21 John Freeman
114 21 John Freeman
* *Error handling*
115 29 John Freeman
As of this writing (7/14/14) there has not yet been extensive user feedback concerning DAQInterface; despite this, certain potential problems have been anticipated and are handled within DAQInterface. These problems include:
116 18 John Freeman
# An artdaq process returns an error state after a transition request, or an exception is thrown by the XML-RPC library during the request
117 19 John Freeman
# During periodic checks, one or more artdaq processes expected to exist are not found
118 18 John Freeman
119 1 John Freeman
In either case, an error is reported via 0MQ to run control, and the "Recover" transition is automatically triggered. This transition is a fairly blunt instrument: it will kill any remaining artdaq processes and return DAQInterface to its original state of "stopped" (i.e., one in which it requires the "init" transition before anything else is done). 
120 18 John Freeman
121 36 John Freeman
In order to see this for yourself, you can deliberately sabotage one of the transitions.  E.g.,  you can replace one of these filenames listed in the config.txt file with one of your own files intentionally designed to be improper FHiCL; this will then trigger a "recover" transition automatically when an "init" transition is requested. The same thing will occur if you use the name of a file which doesn't exist. After the "recover" transition, you can then use the "lbnecmd check" command to see for yourself that DAQ Interface has returned to its original state. Note that currently, if recover sees that the artdaq processes don't exist, it will raise an exception, which will in turn trigger DAQInterface to end itself. In general, setting "debug level" to a high value is a good idea for troubleshooting if something goes wrong (although a sufficiently high value may simply obscure things for the end user). 
122 18 John Freeman
123 18 John Freeman
Please note that if you issue an "init" transition and then follow it with a "terminate" transition, you'll see an exception in the artdaq terminal window which looks like the snippet below; this is because statistics collection which occurs during termination will fail if no data's been collected, which is expected:
124 18 John Freeman
125 18 John Freeman
<pre>
126 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014:  Time Summary: 
127 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014:  Min: 0
128 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014:  Max: 0
129 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014:  Avg: inf
130 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014: %MSG-s ArtException:  Aggregator-lbnedaqtest01-5265 JobSetup
131 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014: cet::exception caught in art
132 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014: ---- DataCorruption BEGIN
133 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014:   NetMonInputDetail: Could not receive message!
134 18 John Freeman
Tue Jul 08 14:16:33 -0500 2014: ---- DataCorruption END
135 1 John Freeman
Tue Jul 08 14:16:33 -0500 2014: %MSG
136 27 John Freeman
Tue Jul 08 14:16:33 -0500 2014: %MSG-s ArtException:  Aggregator-lbnedaqtest01-5266 JobSetup
137 27 John Freeman
Tue Jul 08 14:16:33 -0500 2014: cet::exception caught in art
138 28 John Freeman
Tue Jul 08 14:16:33 -0500 2014: ---- DataCorruption BEGIN
139 28 John Freeman
Tue Jul 08 14:16:33 -0500 2014:   NetMonInputDetail: Could not receive message!
140 27 John Freeman
Tue Jul 08 14:16:33 -0500 2014: ---- DataCorruption END
141 27 John Freeman
</pre>
142 1 John Freeman
143 1 John Freeman
* *Troubleshooting*
144 1 John Freeman
** *Your change to daqinterface.py doesn't seem to do anything*
145 1 John Freeman
Make sure you kill the existing daqinterface process and restart it
146 1 John Freeman
** *On the initial transition ("lbnecmd init daq"), you see "error: [Errno 111] Connection refused"*
147 36 John Freeman
If a "Recover" is triggered and you can see via "lbnecmd check" that DAQInterface is in the "stopped" state, try initializing again. If that doesn't work, you can try increasing the value of the "pause before initialization" variable in the docs/config.txt file. Empirically, it appears there needs to be a pause of at least 4 seconds on lbnedaqtest01.fnal.gov before the FHiCL documents can be successfully sent via XML-RPC to the processes; increasing this value may make it less likely that the "Connection refused" error occurs.