1 1 John Freeman
2 211 John Freeman
John Freeman, Jan-9-2016:
3 1 John Freeman
4 217 John Freeman
This wiki page used to contain instructions on how to run the classic DAQInterface application for the 35ton experiment. Since 35ton, DAQInterface has been modified, and is now designed for general use across all experiments. Getting it installed and running takes only a couple of minutes; see https://cdcvs.fnal.gov/redmine/projects/artdaq-utilities/wiki/Artdaq-daqinterface for how to do this. Note that the instructions assume that you're working with the artdaq-demo DAQ software package rather than protoDUNE's lbne-artdaq DAQ software package; consequently the following modifications to the instructions on the new DAQInterface wiki apply
5 183 John Freeman
6 217 John Freeman
* After checking out artdaq-utilities-daqinterface, cd into it and run "git checkout protodune"; this will reduce the number of changes you'll need to make to tailor the package to your environment (e.g., it replaces references to artdaq-demo with references to lbne-artdaq, etc.)
7 215 John Freeman
* Make sure you've already got the 35ton configuration repo checked out - i.e., that you've run "git clone http://cdcvs.fnal.gov/projects/lbne-daq-config" in the directory where you wish to install lbne-daq-config
8 217 John Freeman
* Modify ./rc/control/config_functions_local.py so that the "config_dirname" variable at the top of the "get_config_info_base" function refers to the full path of the 35ton configuration repo
9 218 John Freeman
* Unlike in the standard instructions, the configuration you'll be using is called "demo_safemode" rather than "demo". This is already accounted for in the ./bin/just_do_it.sh script; however if you send a manual config transition you'll want to take this into account (i.e., you'll want to send "./bin/send_transition.sh config demo_safemode")
10 1 John Freeman
11 216 John Freeman
Besides this, following the instructions on the DAQInterface wiki will get you up and running with lbne-artdaq's ToySimulator- just keep in mind that where the documentation refers to artdaq-demo, you'll be working with lbne-artdaq.