Tim Nicholls, 10/03/2014 09:26 AM


Results of integration with prototype RCE system Oct 2014

System configuration

ATCA shelf with 1 COB, containing 4xDPMs (8RCEs) and 1xDTM installed. Setup on DAQ internal network with hostnames lbnedpm0-8, lbnedpm0, lbnecob-sm (shelf manager).
RCEs mount /data/lbnedaq/cob_nfs from lbne35t-gateway01

lbne-artdaq system in /data/lbnedaq/rce ran with 2xRCEs (DPM0,1) in 2x2x2 mode on lbnedaq3

RCE data transfer firmware/software set up to generate 3xmicroslices per second. BoardReader configured to create 1 millislice per 3 microslices, i.e. 1Hz of fragments.

Wrote data file in this mode, stored on system as /data/lbnedaq/data/lbne_r001000_sr01_20141003T134235.root