Project

General

Profile

Wiki » History » Version 275

Jason St. John, 07/07/2016 12:40 AM

1 104 Jennifer Raaf
!https:/redmine/attachments/download/17373/Lariat_Logo_256.jpg!  
2 257 Jason St. John
3 272 Jennifer Raaf
LArIAT shift: *+1 9293 LARIAT* (= +1 929 352 7428)
4 218 Jason St. John
ROC West x5413
5 1 William Badgett
MCenter Control Room (MC-CR) x3726 or x8871
6 1 William Badgett
Internationally: prefix *+1 630 840* to the above
7 257 Jason St. John
8 241 Jason St. John
9 1 William Badgett
h1. Shifter Stuff
10 1 William Badgett
11 147 Jason St. John
* [[Before your first shift at LArIAT]]
12 254 Jason St. John
* If remote or starting local shift from scratch: "How to Set up your Shift Station":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/How_to_set_up_your_shift_station
13 249 Jason St. John
* +[[LArIAT Run 2 Shifter Instructions]]+ (April 2016)
14 207 Luke Batten
** [[Run Plan]]
15 202 Jason St. John
** "LArIAT Expert Call List":http://lariat.fnal.gov/internal/internal.html  (User is "lariat", password same as docdb)
16 248 Jason St. John
17 248 Jason St. John
{{toc}}
18 1 William Badgett
19 171 Jason St. John
h2. Link summary ( [[quick start]] )
20 166 Steven Dytman
21 245 Jason St. John
* "Live event viewer":http://lariat-wbm.fnal.gov/lariat/evd.html snapshots
22 197 Jason St. John
* "Accelerator Schedule":http://www-ad.fnal.gov/ops/schedule.html  (power outages, etc)
23 270 William Badgett
* "LArIAT eLog":http://dbweb0.fnal.gov/ECL/lariat/E/index  For making/ending access, starting/ending shifts.
24 210 Luke Batten
* [[LArIAT DAQ Instructions]] (February 2016)
25 237 Jason St. John
* "LArIAT Run Status Webpage":http://lariat-wbm.fnal.gov/lariat/run-alert.html
26 196 Ryan Linehan
* "LArIAT Run Summary Webpage":http://lariat-wbm.fnal.gov/wbm/servlet/LariatRunSummary
27 213 Luke Batten
* "LArIAT Online DQM":http://lariat-dqm.fnal.gov (works with VPN or VNC or on-site only, for now)
28 164 Johnny Ho
* How to use the [[event viewers]]
29 1 William Badgett
* "Synoptic":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring
30 250 Jason St. John
* "Beam monitoring (ACNET)":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Using_ACNET_for_monitoring?parent=Wiki
31 247 Jason St. John
* "Beams Division E-Log":https://www-bd.fnal.gov/Elog/?logNames=Booster%2C+External+Beamlines%2C+Linac%2C+Main+Injector%2C+Operations
32 1 William Badgett
* "MC7 WebCam":http://131.225.176.26/
33 1 William Badgett
34 151 Jason St. John
h3. Important knowledge
35 1 William Badgett
36 149 Jason St. John
* "List of MC7 ACNET devices":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/MC7_in_ACNET
37 149 Jason St. John
* [[MC-7 Enclosure Layout]]
38 1 William Badgett
* "In case the beam TVs are off":http://www-bd.fnal.gov/notifyservlet/www?project=&refresh=on&infolinks=top
39 1 William Badgett
* [[The LArIAT supercycle]] _How DAQ operations relate to the main injector supercycle_ 
40 151 Jason St. John
* "Hardware-Connections-and-Configurations":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Wiki#Hardware-Connections-and-Configurations
41 151 Jason St. John
* "Electronic Hardware Documentation":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Wiki#Electronic-Hardware-Documentation
42 132 Jason St. John
43 149 Jason St. John
h3. Obsolete links
44 1 William Badgett
45 202 Jason St. John
* [[LArIAT Run 1 Shifter Instructions]] (June 2015)
46 149 Jason St. John
* -LArIAT Engineering Run (Aug 2014) [[How to Run the Lariat Data Acquisition]]- (OBSOLETE)
47 1 William Badgett
* -"Shifter Instructions":https://docs.google.com/document/d/1mlN_UIOCqwhe0cFiU7mRc3-lxDZhY-4TmIy23rOzILI/pub August 2014- (Some obsolete information)
48 164 Johnny Ho
* -How to make [[Lariat DAQ Plots]]- (OBSOLETE)
49 149 Jason St. John
50 83 Jason St. John
h1. Troubleshooting 
51 1 William Badgett
52 152 Jason St. John
Any time day or night, please call experts if you are in need of help and the answer is not provided below.
53 152 Jason St. John
54 274 Jason St. John
h2. *VNC Shared Desktop*
55 274 Jason St. John
56 274 Jason St. John
h3. *'VNC server closed connection'* might mean that the vnc server on lariat-cr-02 is not running. 
57 274 Jason St. John
58 274 Jason St. John
Log on to lariat-cr-02 and check if the X11 vnc sever is running:
59 274 Jason St. John
60 274 Jason St. John
<pre>
61 274 Jason St. John
$ ps aux | grep vnc 
62 274 Jason St. John
lariat 31537 0.0 0.0 103308 860 pts/5 S+ 00:12 0:00 grep vnc 
63 274 Jason St. John
</pre>
64 274 Jason St. John
65 274 Jason St. John
66 275 Jason St. John
Re-launched it:
67 275 Jason St. John
68 275 Jason St. John
[lariat@lariat-cr-02 ~]$ x11vnc -create -localhost -xinerama -display :0 -shared -many -forever -bg -rfbauth ~/.x11vnc/passwd
69 275 Jason St. John
70 275 Jason St. John
Checked that it is running now:
71 275 Jason St. John
72 275 Jason St. John
[lariat@lariat-cr-02 ~]$ ps aux | grep vnc
73 275 Jason St. John
lariat 31670 8.4 1.6 194032 61944 ? Ss 00:14 0:10 x11vnc -create -localhost -xinerama -display :0 -shared -many -forever -bg -rfbauth /home/lariat/.x11vnc/passwd
74 275 Jason St. John
lariat 31753 0.0 0.0 103308 860 pts/5 S+ 00:16 0:00 grep vnc
75 275 Jason St. John
76 275 Jason St. John
77 275 Jason St. John
...and shifter is able to connect (the most important part!)
78 275 Jason St. John
79 152 Jason St. John
h2. *Trigger and DAQ system*
80 152 Jason St. John
81 188 Jason St. John
When the DAQ crashes, please post the relevant information to [[DAQerrors]] for experts to study.
82 188 Jason St. John
83 187 Jason St. John
h3. Common failures:
84 187 Jason St. John
85 258 Jason St. John
* Communication failure with the front ends. Trying clearing it with 
86 258 Jason St. John
<pre>lariatReset</pre>
87 258 Jason St. John
Wait a few minutes and then try the @go 480@ command again.
88 243 Jason St. John
* Unable to start a new run: <pre>lost connection
89 243 Jason St. John
Permission denied (gssapi-keyex,gssapi-with-mic)</pre>
90 271 Roberto Acciarri
** Log out of the DAQ machine, and use the command *@kticket@* to pick up a fresh kerberos ticket with the special principal that we use for the DAQ: @lariat/lariat@lariat-daq00.fnal.gov@FNAL.GOV@. Check for this success with @klist@. Then log back in to the DAQ machine and start a new run.
91 187 Jason St. John
* DAQ fails with @ERROR: ReadRegisgter ACQUISITION_STATUS CAEN_DGTZ_CommError BoardId 0@  wait 2 minutes, then try to start again.
92 187 Jason St. John
** Try issuing the command @lariatReset 0 1@ waiting more then 5 seconds, and trying again.
93 187 Jason St. John
This command is appropriate when one sees any type of "CAEN_DGTZ" error.  This command will NOT help the persistent ports error.
94 187 Jason St. John
* DAQ fails with @Found persistent communication port still open@
95 187 Jason St. John
** Wait 8 minutes for the ports to clear, then try again.
96 224 Pawel Kryczynski
* DAQ fails with "An exception occurred when trying to send a message to ..." 
97 223 Pawel Kryczynski
** Check that the terminal you are running the DAQ from is indeed lariat-daq00 (or a screen within it).  Output from @klist@ should show the default principal as "lariat/lariat/lariat-cr-02.fnal.gov@FNAL.GOV" or similar if running from a screen off lariat-daq00 from the ROC-West station.
98 242 Jason St. John
** Run number failed increment or has reset to a low number such as 1: Stop the run and then on the DAQ terminal edit @/opt/lariat-online/config/runNumber.dat@ to correct the run number. Start new run after.
99 187 Jason St. John
100 187 Jason St. John
h3. Other failures: 
101 187 Jason St. John
102 1 William Badgett
* If the DAQ is having trouble talking to the crates, try issuing the command @lariatReset 0 1@ waiting more then 5 seconds, and trying again.
103 187 Jason St. John
This command is appropriate when one sees any type of "CAEN_DGTZ" error.  This command will NOT help the persistent ports error.
104 227 Jason St. John
* *No triggers at all* If the trigger crate has been power cycled and the V1495 is not emitting triggers: [[Reset1495]]
105 226 Jason St. John
* *Run Status page not updating* 
106 226 Jason St. John
** Try refreshing the page. 
107 227 Jason St. John
** If the ACNET node has gone down (as in a power loss) may need to re-start the tomcat servlet: @ssh tomcat@lariat-wbm.fnal.gov@, then @kitty@.  (Yep, "kitty.")
108 83 Jason St. John
109 152 Jason St. John
h2. *Wire Chambers*
110 152 Jason St. John
111 228 Jason St. John
Nominal Voltages:
112 229 Flor de maria Blaszczyk
|_. WC1 | -2425 |
113 228 Jason St. John
|_. WC2 | -2400 |
114 229 Flor de maria Blaszczyk
|_. WC3 | -2425 |
115 228 Jason St. John
|_. WC4 | -2450 |
116 228 Jason St. John
117 269 Jason St. John
* If the wire chambers HV trips: "instructions to control wire chamber voltages":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#4-Synoptic-power-supplies-controls
118 135 Jason St. John
* If the wire chambers are acting strangely: "remote power cycling instructions":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Communicating_with_the_wire_chambers including mini-DAQ and telnet interface.
119 83 Jason St. John
* If the wire chamber system is skipping spill numbers, it may be a high trigger rate (> 30 k per spill).  The wire chamber controller may still be reading out the hits from the last spill.
120 1 William Badgett
121 231 Flor de maria Blaszczyk
h2. *High voltage for the wire chambers, TPC wireplane bias, cryo PMTs*
122 230 Flor de maria Blaszczyk
123 256 Jason St. John
%{color:red}ICathode HV trips off due to LAr level interlock.%
124 240 Jason St. John
[[Drift HV]] TPC Cathode Voltage
125 240 Jason St. John
126 256 Jason St. John
"*General Instructions for controls via Synoptic*":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#section-10
127 230 Flor de maria Blaszczyk
128 236 Flor de maria Blaszczyk
Also valid for some of the muon range stack paddles (1-8), the halo veto and 1 aerogel PMT.
129 236 Flor de maria Blaszczyk
130 230 Flor de maria Blaszczyk
*ONLY IF SYNOPTIC DOESN'T WORK* "Instructions for controls via ACNET":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_ACNET_to_power_up_the_power_supplies
131 230 Flor de maria Blaszczyk
132 230 Flor de maria Blaszczyk
* The readback voltage doesn't make any sense, is of the wrong polarity and/or is way above the nominal value, but just for a fraction of time.
133 230 Flor de maria Blaszczyk
This is most likely just a glitch in the readout, please ignore if it happens once or twice. If it happens too frequently, set voltage to 0, turn off the power supply and report it. 
134 230 Flor de maria Blaszczyk
135 230 Flor de maria Blaszczyk
* The readback voltage doesn't make any sense, is of the wrong polarity and is way above the nominal value, and the value is stable~ish (you might see small fluctuations over time)
136 230 Flor de maria Blaszczyk
This is a typical symptom of a bad power supply. Try to set it back to 0, turn it off and disconnect the SHV cable. If the readout values remain the same, it confirms there is a hardware problem. Please contact Brian Fellenz for repairs if we don't have a spare for that unit.
137 230 Flor de maria Blaszczyk
138 230 Flor de maria Blaszczyk
FYI, the power supplies have a given voltage rating and cannot physically deliver voltages beyond that range. Also, their polarities cannot be swapped so if you see the wrong sign on the readout ie a positive voltage on a negative power supply or vice versa, then you can be sure the unit is broken or you have a problem somewhere else in the system.
139 230 Flor de maria Blaszczyk
- Bias voltage rating: - 500 V for the shield and induction planes, + 500 V for the collection plane.
140 230 Flor de maria Blaszczyk
- ELT and Hamamatsu PMTs: +2000 V
141 253 Flor de maria Blaszczyk
- Wire chambers: - 5000 V
142 230 Flor de maria Blaszczyk
- All of the other units: -2000 V
143 230 Flor de maria Blaszczyk
144 230 Flor de maria Blaszczyk
* Something went wrong during a ramp, I need to turn off the supply!
145 230 Flor de maria Blaszczyk
There is an interlock that prevents you from using the normal fast controls on the power supply when a ramp is on-going. First, *stop the ramp by clicking on the STOP button*. This will stop the ramp and clear the interlock. If you need to go back to 0 quickly, use the fast controls to set the voltage to 0 and *don't forget to turn off the supply!*
146 230 Flor de maria Blaszczyk
147 230 Flor de maria Blaszczyk
*Even if the controls appear not to respond, set the voltage to 0 and turn the supply off*. Contact Charlie Briegel first and describe the problem in detail. If you can and if it's safe, disconnect the SHV cable from the power supply. If the readback values remain the same, then the power supply is broken.
148 230 Flor de maria Blaszczyk
149 232 Flor de maria Blaszczyk
* *ACNET controls expert: Charles (Charlie) Briegel, x4510 briegel@fnal.gov*  
150 232 Flor de maria Blaszczyk
* *VME power supplies repairs / replacements: Brian Fellenz, x2512 fellenz@fnal.gov*
151 230 Flor de maria Blaszczyk
152 225 Roberto Acciarri
h2. *Event Viewer*
153 225 Roberto Acciarri
154 225 Roberto Acciarri
* If the event viewer stops cycling through the events and the terminal from which it is running shows a list of lines saying something like _"event XX in file, but on event 0"_ with _XX_ any number,
155 225 Roberto Acciarri
** _*ctrl+z*_ 
156 225 Roberto Acciarri
** _*ps -def*_ to look at the processes list. Look for the job ID of the process _"python /lariat/app/users/EventViewer/..."_ 
157 225 Roberto Acciarri
** _*kill -9 JobID*_ to kill the event viewer
158 268 Jason St. John
** open a new event viewer <pre>ssh lariat@lariatgpvm01.fnal.gov 
159 268 Jason St. John
cd /lariat/app/users/EventViewer/; source SETUP_ONLINE_EVENTVIEWER.sh</pre>
160 225 Roberto Acciarri
161 268 Jason St. John
* If the problem persists and/or become more frequent, exit the session you are in and try to connect from a different gpvm machine
162 181 Jason St. John
163 181 Jason St. John
h2. Power Cycle the ASICs (TPC Wire Noise)
164 181 Jason St. John
165 217 Flor de maria Blaszczyk
* Anecdotal evidence has shown that analog noise on the TPC wire readout channels can be 
166 217 Flor de maria Blaszczyk
alleviated by power cycling the TPC electronics: ASICs and Warm Receiver/Drivers
167 219 Flor de maria Blaszczyk
* You can remotely power cycle the TPC electronics.  Log onto lariat-gateway00.fnal.gov with X-forwarding enabled, type "firefox", and go to http://lariat-pdu02.fnal.gov.  Usename "ftbf" (password posted on whiteboard in MC7).  Choose the *CYCLE* option, which will automatically give a 60 
168 220 Flor de maria Blaszczyk
second powerless interlude.
169 220 Flor de maria Blaszczyk
* Further important informations can be found on the white board in MC-CR.
170 219 Flor de maria Blaszczyk
* This mechanism is controlled by a smart power distribution unit (PDU) located under the 
171 220 Flor de maria Blaszczyk
TPC electronics power supply near the cryostat in the enclosure.   Due to electrical safety 
172 220 Flor de maria Blaszczyk
rules you must *NOT* use any of the other outlets on this PDU.  Do *NOT* remove the protective 
173 219 Flor de maria Blaszczyk
outlet covers at any time.
174 220 Flor de maria Blaszczyk
!https://redmine.fnal.gov/redmine/attachments/download/25467/lariat-pdu02-cycle.png!
175 220 Flor de maria Blaszczyk
176 1 William Badgett
h2. Recover from a LAr level interlock
177 220 Flor de maria Blaszczyk
178 221 Flor de maria Blaszczyk
Assuming the LAr Level dropped low enough to trip off the TPC Cathode power supply, and maybe you even powered down the PMTs.
179 221 Flor de maria Blaszczyk
180 221 Flor de maria Blaszczyk
# Be sure HV is set to zero for these: Cathode Drift, Wire Bias, cryo-PMTs
181 220 Flor de maria Blaszczyk
How to control the [[Drift HV]]
182 219 Flor de maria Blaszczyk
# Power down the ASICs. (They should be off when TPC voltages change.)
183 220 Flor de maria Blaszczyk
# Bring up the Cathode
184 219 Flor de maria Blaszczyk
# Bring up the Wire Bias
185 221 Flor de maria Blaszczyk
# Bring up the ASICs
186 219 Flor de maria Blaszczyk
# Bring up the PMTs
187 219 Flor de maria Blaszczyk
188 219 Flor de maria Blaszczyk
189 219 Flor de maria Blaszczyk
190 217 Flor de maria Blaszczyk
h2. Synoptic troubleshooting
191 217 Flor de maria Blaszczyk
192 217 Flor de maria Blaszczyk
%{color:red}"Synoptic Troubleshooting":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#Troubleshooting%
193 217 Flor de maria Blaszczyk
194 266 Johnny Ho
h2. DQM troubleshooting
195 266 Johnny Ho
196 266 Johnny Ho
If the DQM is %{color:red}flashing red%...
197 267 Johnny Ho
198 266 Johnny Ho
* Check to see if the DAQ is running. If it isn't running, you should start a new run!
199 266 Johnny Ho
* Check the "LArIAT Run Status page":http://lariat-wbm.fnal.gov/lariat/run-alert.html. If the number under *Complete Files Waiting* is greater than 10, please call a data handling expert!
200 267 Johnny Ho
* Check the disk space on the @/lariat/data@ mount with the command @df -h /lariat/data@ on a @lariatgpvm@ or @lariat-daq@ machine. If the disk space is 100% full, please call a DQM expert!
201 266 Johnny Ho
202 260 Monica Nunes
203 260 Monica Nunes
h2. PB S60 PPD Params
204 261 Monica Nunes
205 261 Monica Nunes
If F:MC7AN , F:MC7ANB and F:MC7ANP show the values 1  -6 (in red), this is probably a communication problem, where we are not receiving data from them.
206 261 Monica Nunes
Usually it comes back in a few minutes. 
207 265 Monica Nunes
If not, call the MCR and ask them if they can see those values.
208 217 Flor de maria Blaszczyk
209 68 Michael Kordosky
h1. Hardware Connections and Configurations
210 1 William Badgett
211 141 William Badgett
* [[TPC Channel Mapping]]
212 51 Jason St. John
* [[Non-TPC Detectors]] *Naming and numbering in MC7*
213 133 Jason St. John
* "Cable Patch Panel Spreadsheet":http://goo.gl/JXiH8Y
214 54 Jason St. John
* [[Connections on the Control Room Patch Panel]]
215 54 Jason St. John
216 51 Jason St. John
* [[Logical inputs to the CAEN V1740]]
217 51 Jason St. John
* [[Connections into the WUT TDC]]
218 51 Jason St. John
* [[Connections into the V1751 Digitizer]]
219 1 William Badgett
* [[Trigger inputs|Connections in/out of the V1495 Trigger]]
220 68 Michael Kordosky
* [[Logic pulse widths and discriminator thresholds]]
221 68 Michael Kordosky
* [[WUT configuration]]
222 74 William Badgett
* [[Timing of ACnet TCLK Events]]
223 140 William Badgett
* The [[Teensy]] LAr ASIC controller's configuration
224 50 Michael Kordosky
225 138 Roberto Acciarri
* [[Punch Through counters voltages and rates ]]
226 138 Roberto Acciarri
227 102 Jason St. John
h1. Electronic Hardware Documentation
228 45 Michael Kordosky
229 51 Jason St. John
* Link to LArIAT eLog http://dbweb0.fnal.gov/ECL/lariat
230 51 Jason St. John
* [[LariatOnlineGit]] Accessing the LArIAT Online GIT repository
231 98 Brian Rebel
* [[Building LArIATOnline with CMake]]
232 44 Michael Kordosky
233 51 Jason St. John
* [[LArIAT TPC Readout Parameters]]
234 185 William Badgett
* [[LArASIC Preamp Documentation from BNL]]
235 51 Jason St. John
* [[LArIAT DAQ Commercial Products]] Technical Documentation and Firmware Files
236 101 William Badgett
* [[LArIAT CAEN Products]] Technical Documentation and Firmware Files
237 51 Jason St. John
* Test Beam Wire Chamber Sten Hensen's [[TDC Readout Documentation]]
238 89 William Badgett
* WUT Wave Union TDC: [[Jinyuan's TDC Documentation]]
239 51 Jason St. John
* [[v1495 notes]] Notes and working area for the V1495 and V2718
240 273 James Zhu
* "V1495 docs on DocDB":http://lartpc-docdb.fnal.gov:8080/cgi-bin/ShowDocument?docid=1698, built from source:fpga/doc/
241 195 Johnny Ho
* [[A3818 PCI optical controller]] links
242 35 Michael Kordosky
243 1 William Badgett
* [[DAQ Configuration]] settings, parameters, starting a run
244 51 Jason St. John
* [[Raw Data Format and Readout Source code]]
245 100 John Freeman
* [[All things lariat-artdaq]] (UPDATED 11/5/14)
246 154 Jason St. John
* [[Interpreting Wire Chamber TDC Data]]
247 36 Michael Kordosky
248 54 Jason St. John
* [[LArIAT Test Stand]] Photographs
249 47 Michael Kordosky
250 72 Michael Kordosky
h1. Diagnostic and Control Software
251 72 Michael Kordosky
252 73 Michael Kordosky
_Test programs in the_ lariat-online/daq/src _directory_
253 73 Michael Kordosky
254 72 Michael Kordosky
* [[DumpDigitizerData]]
255 72 Michael Kordosky
* [[SummarizeDAQOutput]]
256 72 Michael Kordosky
* [[Reset1495]]
257 72 Michael Kordosky
* [[ScalarReadout]]
258 97 Pawel Kryczynski
* [[Data_quality_monitoring_module]]
259 72 Michael Kordosky
260 139 William Badgett
* CAEN's [[WaveDump]] utility
261 139 William Badgett
262 75 Jason St. John
h1. Examining the WC mini DAQ ASCII data
263 75 Jason St. John
264 75 Jason St. John
The Processor makes TTrees from the ASCII files saved by @mc7-daq.py@
265 82 Jason St. John
[[WC MiniDAQ Data Processor]]
266 75 Jason St. John
267 153 Jason St. John
h1. Data Files from the year 2013
268 76 Will Flanagan
269 85 William Badgett
Data files for various beam conditions can be found in the [[DataFiles]] page.
270 85 William Badgett
271 51 Jason St. John
h1. Meetings
272 51 Jason St. John
273 51 Jason St. John
* [[Connecting to LArIAT ReadyTalk]]
274 198 Johnny Ho
275 1 William Badgett
h1. Miscellaneous
276 198 Johnny Ho
277 216 Luke Batten
* The control room shifter computer (MCenter) can be logged into as ftbf_user@ftbflx18.fnal.gov after passing through lariat-gateway.fnal.gov
278 198 Johnny Ho
* [[Proxy using SSH tunnel]]