Project

General

Profile

Wiki » History » Version 272

Jennifer Raaf, 06/15/2016 10:24 PM

1 104 Jennifer Raaf
!https:/redmine/attachments/download/17373/Lariat_Logo_256.jpg!  
2 257 Jason St. John
3 272 Jennifer Raaf
LArIAT shift: *+1 9293 LARIAT* (= +1 929 352 7428)
4 218 Jason St. John
ROC West x5413
5 1 William Badgett
MCenter Control Room (MC-CR) x3726 or x8871
6 1 William Badgett
Internationally: prefix *+1 630 840* to the above
7 257 Jason St. John
8 241 Jason St. John
9 1 William Badgett
h1. Shifter Stuff
10 1 William Badgett
11 147 Jason St. John
* [[Before your first shift at LArIAT]]
12 254 Jason St. John
* If remote or starting local shift from scratch: "How to Set up your Shift Station":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/How_to_set_up_your_shift_station
13 249 Jason St. John
* +[[LArIAT Run 2 Shifter Instructions]]+ (April 2016)
14 207 Luke Batten
** [[Run Plan]]
15 202 Jason St. John
** "LArIAT Expert Call List":http://lariat.fnal.gov/internal/internal.html  (User is "lariat", password same as docdb)
16 248 Jason St. John
17 248 Jason St. John
{{toc}}
18 1 William Badgett
19 171 Jason St. John
h2. Link summary ( [[quick start]] )
20 166 Steven Dytman
21 245 Jason St. John
* "Live event viewer":http://lariat-wbm.fnal.gov/lariat/evd.html snapshots
22 197 Jason St. John
* "Accelerator Schedule":http://www-ad.fnal.gov/ops/schedule.html  (power outages, etc)
23 270 William Badgett
* "LArIAT eLog":http://dbweb0.fnal.gov/ECL/lariat/E/index  For making/ending access, starting/ending shifts.
24 210 Luke Batten
* [[LArIAT DAQ Instructions]] (February 2016)
25 237 Jason St. John
* "LArIAT Run Status Webpage":http://lariat-wbm.fnal.gov/lariat/run-alert.html
26 196 Ryan Linehan
* "LArIAT Run Summary Webpage":http://lariat-wbm.fnal.gov/wbm/servlet/LariatRunSummary
27 213 Luke Batten
* "LArIAT Online DQM":http://lariat-dqm.fnal.gov (works with VPN or VNC or on-site only, for now)
28 164 Johnny Ho
* How to use the [[event viewers]]
29 1 William Badgett
* "Synoptic":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring
30 250 Jason St. John
* "Beam monitoring (ACNET)":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Using_ACNET_for_monitoring?parent=Wiki
31 247 Jason St. John
* "Beams Division E-Log":https://www-bd.fnal.gov/Elog/?logNames=Booster%2C+External+Beamlines%2C+Linac%2C+Main+Injector%2C+Operations
32 1 William Badgett
* "MC7 WebCam":http://131.225.176.26/
33 1 William Badgett
34 151 Jason St. John
h3. Important knowledge
35 1 William Badgett
36 149 Jason St. John
* "List of MC7 ACNET devices":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/MC7_in_ACNET
37 149 Jason St. John
* [[MC-7 Enclosure Layout]]
38 1 William Badgett
* "In case the beam TVs are off":http://www-bd.fnal.gov/notifyservlet/www?project=&refresh=on&infolinks=top
39 1 William Badgett
* [[The LArIAT supercycle]] _How DAQ operations relate to the main injector supercycle_ 
40 151 Jason St. John
* "Hardware-Connections-and-Configurations":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Wiki#Hardware-Connections-and-Configurations
41 151 Jason St. John
* "Electronic Hardware Documentation":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Wiki#Electronic-Hardware-Documentation
42 132 Jason St. John
43 149 Jason St. John
h3. Obsolete links
44 1 William Badgett
45 202 Jason St. John
* [[LArIAT Run 1 Shifter Instructions]] (June 2015)
46 149 Jason St. John
* -LArIAT Engineering Run (Aug 2014) [[How to Run the Lariat Data Acquisition]]- (OBSOLETE)
47 1 William Badgett
* -"Shifter Instructions":https://docs.google.com/document/d/1mlN_UIOCqwhe0cFiU7mRc3-lxDZhY-4TmIy23rOzILI/pub August 2014- (Some obsolete information)
48 164 Johnny Ho
* -How to make [[Lariat DAQ Plots]]- (OBSOLETE)
49 149 Jason St. John
50 83 Jason St. John
h1. Troubleshooting 
51 1 William Badgett
52 152 Jason St. John
Any time day or night, please call experts if you are in need of help and the answer is not provided below.
53 152 Jason St. John
54 152 Jason St. John
h2. *Trigger and DAQ system*
55 152 Jason St. John
56 188 Jason St. John
When the DAQ crashes, please post the relevant information to [[DAQerrors]] for experts to study.
57 188 Jason St. John
58 187 Jason St. John
h3. Common failures:
59 187 Jason St. John
60 258 Jason St. John
* Communication failure with the front ends. Trying clearing it with 
61 258 Jason St. John
<pre>lariatReset</pre>
62 258 Jason St. John
Wait a few minutes and then try the @go 480@ command again.
63 243 Jason St. John
* Unable to start a new run: <pre>lost connection
64 243 Jason St. John
Permission denied (gssapi-keyex,gssapi-with-mic)</pre>
65 271 Roberto Acciarri
** Log out of the DAQ machine, and use the command *@kticket@* to pick up a fresh kerberos ticket with the special principal that we use for the DAQ: @lariat/lariat@lariat-daq00.fnal.gov@FNAL.GOV@. Check for this success with @klist@. Then log back in to the DAQ machine and start a new run.
66 187 Jason St. John
* DAQ fails with @ERROR: ReadRegisgter ACQUISITION_STATUS CAEN_DGTZ_CommError BoardId 0@  wait 2 minutes, then try to start again.
67 187 Jason St. John
** Try issuing the command @lariatReset 0 1@ waiting more then 5 seconds, and trying again.
68 187 Jason St. John
This command is appropriate when one sees any type of "CAEN_DGTZ" error.  This command will NOT help the persistent ports error.
69 187 Jason St. John
* DAQ fails with @Found persistent communication port still open@
70 187 Jason St. John
** Wait 8 minutes for the ports to clear, then try again.
71 224 Pawel Kryczynski
* DAQ fails with "An exception occurred when trying to send a message to ..." 
72 223 Pawel Kryczynski
** Check that the terminal you are running the DAQ from is indeed lariat-daq00 (or a screen within it).  Output from @klist@ should show the default principal as "lariat/lariat/lariat-cr-02.fnal.gov@FNAL.GOV" or similar if running from a screen off lariat-daq00 from the ROC-West station.
73 242 Jason St. John
** Run number failed increment or has reset to a low number such as 1: Stop the run and then on the DAQ terminal edit @/opt/lariat-online/config/runNumber.dat@ to correct the run number. Start new run after.
74 187 Jason St. John
75 187 Jason St. John
h3. Other failures: 
76 187 Jason St. John
77 1 William Badgett
* If the DAQ is having trouble talking to the crates, try issuing the command @lariatReset 0 1@ waiting more then 5 seconds, and trying again.
78 187 Jason St. John
This command is appropriate when one sees any type of "CAEN_DGTZ" error.  This command will NOT help the persistent ports error.
79 227 Jason St. John
* *No triggers at all* If the trigger crate has been power cycled and the V1495 is not emitting triggers: [[Reset1495]]
80 226 Jason St. John
* *Run Status page not updating* 
81 226 Jason St. John
** Try refreshing the page. 
82 227 Jason St. John
** If the ACNET node has gone down (as in a power loss) may need to re-start the tomcat servlet: @ssh tomcat@lariat-wbm.fnal.gov@, then @kitty@.  (Yep, "kitty.")
83 83 Jason St. John
84 152 Jason St. John
h2. *Wire Chambers*
85 152 Jason St. John
86 228 Jason St. John
Nominal Voltages:
87 229 Flor de maria Blaszczyk
|_. WC1 | -2425 |
88 228 Jason St. John
|_. WC2 | -2400 |
89 229 Flor de maria Blaszczyk
|_. WC3 | -2425 |
90 228 Jason St. John
|_. WC4 | -2450 |
91 228 Jason St. John
92 269 Jason St. John
* If the wire chambers HV trips: "instructions to control wire chamber voltages":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#4-Synoptic-power-supplies-controls
93 135 Jason St. John
* If the wire chambers are acting strangely: "remote power cycling instructions":https://redmine.fnal.gov/redmine/projects/lariat-online/wiki/Communicating_with_the_wire_chambers including mini-DAQ and telnet interface.
94 83 Jason St. John
* If the wire chamber system is skipping spill numbers, it may be a high trigger rate (> 30 k per spill).  The wire chamber controller may still be reading out the hits from the last spill.
95 1 William Badgett
96 231 Flor de maria Blaszczyk
h2. *High voltage for the wire chambers, TPC wireplane bias, cryo PMTs*
97 230 Flor de maria Blaszczyk
98 256 Jason St. John
%{color:red}ICathode HV trips off due to LAr level interlock.%
99 240 Jason St. John
[[Drift HV]] TPC Cathode Voltage
100 240 Jason St. John
101 256 Jason St. John
"*General Instructions for controls via Synoptic*":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#section-10
102 230 Flor de maria Blaszczyk
103 236 Flor de maria Blaszczyk
Also valid for some of the muon range stack paddles (1-8), the halo veto and 1 aerogel PMT.
104 236 Flor de maria Blaszczyk
105 230 Flor de maria Blaszczyk
*ONLY IF SYNOPTIC DOESN'T WORK* "Instructions for controls via ACNET":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_ACNET_to_power_up_the_power_supplies
106 230 Flor de maria Blaszczyk
107 230 Flor de maria Blaszczyk
* The readback voltage doesn't make any sense, is of the wrong polarity and/or is way above the nominal value, but just for a fraction of time.
108 230 Flor de maria Blaszczyk
This is most likely just a glitch in the readout, please ignore if it happens once or twice. If it happens too frequently, set voltage to 0, turn off the power supply and report it. 
109 230 Flor de maria Blaszczyk
110 230 Flor de maria Blaszczyk
* The readback voltage doesn't make any sense, is of the wrong polarity and is way above the nominal value, and the value is stable~ish (you might see small fluctuations over time)
111 230 Flor de maria Blaszczyk
This is a typical symptom of a bad power supply. Try to set it back to 0, turn it off and disconnect the SHV cable. If the readout values remain the same, it confirms there is a hardware problem. Please contact Brian Fellenz for repairs if we don't have a spare for that unit.
112 230 Flor de maria Blaszczyk
113 230 Flor de maria Blaszczyk
FYI, the power supplies have a given voltage rating and cannot physically deliver voltages beyond that range. Also, their polarities cannot be swapped so if you see the wrong sign on the readout ie a positive voltage on a negative power supply or vice versa, then you can be sure the unit is broken or you have a problem somewhere else in the system.
114 230 Flor de maria Blaszczyk
- Bias voltage rating: - 500 V for the shield and induction planes, + 500 V for the collection plane.
115 230 Flor de maria Blaszczyk
- ELT and Hamamatsu PMTs: +2000 V
116 253 Flor de maria Blaszczyk
- Wire chambers: - 5000 V
117 230 Flor de maria Blaszczyk
- All of the other units: -2000 V
118 230 Flor de maria Blaszczyk
119 230 Flor de maria Blaszczyk
* Something went wrong during a ramp, I need to turn off the supply!
120 230 Flor de maria Blaszczyk
There is an interlock that prevents you from using the normal fast controls on the power supply when a ramp is on-going. First, *stop the ramp by clicking on the STOP button*. This will stop the ramp and clear the interlock. If you need to go back to 0 quickly, use the fast controls to set the voltage to 0 and *don't forget to turn off the supply!*
121 230 Flor de maria Blaszczyk
122 230 Flor de maria Blaszczyk
*Even if the controls appear not to respond, set the voltage to 0 and turn the supply off*. Contact Charlie Briegel first and describe the problem in detail. If you can and if it's safe, disconnect the SHV cable from the power supply. If the readback values remain the same, then the power supply is broken.
123 230 Flor de maria Blaszczyk
124 232 Flor de maria Blaszczyk
* *ACNET controls expert: Charles (Charlie) Briegel, x4510 briegel@fnal.gov*  
125 232 Flor de maria Blaszczyk
* *VME power supplies repairs / replacements: Brian Fellenz, x2512 fellenz@fnal.gov*
126 230 Flor de maria Blaszczyk
127 225 Roberto Acciarri
h2. *Event Viewer*
128 225 Roberto Acciarri
129 225 Roberto Acciarri
* If the event viewer stops cycling through the events and the terminal from which it is running shows a list of lines saying something like _"event XX in file, but on event 0"_ with _XX_ any number,
130 225 Roberto Acciarri
** _*ctrl+z*_ 
131 225 Roberto Acciarri
** _*ps -def*_ to look at the processes list. Look for the job ID of the process _"python /lariat/app/users/EventViewer/..."_ 
132 225 Roberto Acciarri
** _*kill -9 JobID*_ to kill the event viewer
133 268 Jason St. John
** open a new event viewer <pre>ssh lariat@lariatgpvm01.fnal.gov 
134 268 Jason St. John
cd /lariat/app/users/EventViewer/; source SETUP_ONLINE_EVENTVIEWER.sh</pre>
135 225 Roberto Acciarri
136 268 Jason St. John
* If the problem persists and/or become more frequent, exit the session you are in and try to connect from a different gpvm machine
137 181 Jason St. John
138 181 Jason St. John
h2. Power Cycle the ASICs (TPC Wire Noise)
139 181 Jason St. John
140 217 Flor de maria Blaszczyk
* Anecdotal evidence has shown that analog noise on the TPC wire readout channels can be 
141 217 Flor de maria Blaszczyk
alleviated by power cycling the TPC electronics: ASICs and Warm Receiver/Drivers
142 219 Flor de maria Blaszczyk
* You can remotely power cycle the TPC electronics.  Log onto lariat-gateway00.fnal.gov with X-forwarding enabled, type "firefox", and go to http://lariat-pdu02.fnal.gov.  Usename "ftbf" (password posted on whiteboard in MC7).  Choose the *CYCLE* option, which will automatically give a 60 
143 220 Flor de maria Blaszczyk
second powerless interlude.
144 220 Flor de maria Blaszczyk
* Further important informations can be found on the white board in MC-CR.
145 219 Flor de maria Blaszczyk
* This mechanism is controlled by a smart power distribution unit (PDU) located under the 
146 220 Flor de maria Blaszczyk
TPC electronics power supply near the cryostat in the enclosure.   Due to electrical safety 
147 220 Flor de maria Blaszczyk
rules you must *NOT* use any of the other outlets on this PDU.  Do *NOT* remove the protective 
148 219 Flor de maria Blaszczyk
outlet covers at any time.
149 220 Flor de maria Blaszczyk
!https://redmine.fnal.gov/redmine/attachments/download/25467/lariat-pdu02-cycle.png!
150 220 Flor de maria Blaszczyk
151 1 William Badgett
h2. Recover from a LAr level interlock
152 220 Flor de maria Blaszczyk
153 221 Flor de maria Blaszczyk
Assuming the LAr Level dropped low enough to trip off the TPC Cathode power supply, and maybe you even powered down the PMTs.
154 221 Flor de maria Blaszczyk
155 221 Flor de maria Blaszczyk
# Be sure HV is set to zero for these: Cathode Drift, Wire Bias, cryo-PMTs
156 220 Flor de maria Blaszczyk
How to control the [[Drift HV]]
157 219 Flor de maria Blaszczyk
# Power down the ASICs. (They should be off when TPC voltages change.)
158 220 Flor de maria Blaszczyk
# Bring up the Cathode
159 219 Flor de maria Blaszczyk
# Bring up the Wire Bias
160 221 Flor de maria Blaszczyk
# Bring up the ASICs
161 219 Flor de maria Blaszczyk
# Bring up the PMTs
162 219 Flor de maria Blaszczyk
163 219 Flor de maria Blaszczyk
164 219 Flor de maria Blaszczyk
165 217 Flor de maria Blaszczyk
h2. Synoptic troubleshooting
166 217 Flor de maria Blaszczyk
167 217 Flor de maria Blaszczyk
%{color:red}"Synoptic Troubleshooting":https://cdcvs.fnal.gov/redmine/projects/lariat-online/wiki/Using_Synoptic_for_monitoring#Troubleshooting%
168 217 Flor de maria Blaszczyk
169 266 Johnny Ho
h2. DQM troubleshooting
170 266 Johnny Ho
171 266 Johnny Ho
If the DQM is %{color:red}flashing red%...
172 266 Johnny Ho
173 267 Johnny Ho
* Check to see if the DAQ is running. If it isn't running, you should start a new run!
174 266 Johnny Ho
* Check the "LArIAT Run Status page":http://lariat-wbm.fnal.gov/lariat/run-alert.html. If the number under *Complete Files Waiting* is greater than 10, please call a data handling expert!
175 266 Johnny Ho
* Check the disk space on the @/lariat/data@ mount with the command @df -h /lariat/data@ on a @lariatgpvm@ or @lariat-daq@ machine. If the disk space is 100% full, please call a DQM expert!
176 267 Johnny Ho
177 266 Johnny Ho
178 260 Monica Nunes
h2. PB S60 PPD Params
179 260 Monica Nunes
180 261 Monica Nunes
If F:MC7AN , F:MC7ANB and F:MC7ANP show the values 1  -6 (in red), this is probably a communication problem, where we are not receiving data from them.
181 261 Monica Nunes
Usually it comes back in a few minutes. 
182 261 Monica Nunes
If not, call the MCR and ask them if they can see those values.
183 265 Monica Nunes
184 217 Flor de maria Blaszczyk
185 68 Michael Kordosky
h1. Hardware Connections and Configurations
186 1 William Badgett
187 141 William Badgett
* [[TPC Channel Mapping]]
188 51 Jason St. John
* [[Non-TPC Detectors]] *Naming and numbering in MC7*
189 133 Jason St. John
* "Cable Patch Panel Spreadsheet":http://goo.gl/JXiH8Y
190 54 Jason St. John
* [[Connections on the Control Room Patch Panel]]
191 54 Jason St. John
192 51 Jason St. John
* [[Logical inputs to the CAEN V1740]]
193 51 Jason St. John
* [[Connections into the WUT TDC]]
194 51 Jason St. John
* [[Connections into the V1751 Digitizer]]
195 1 William Badgett
* [[Trigger inputs|Connections in/out of the V1495 Trigger]]
196 68 Michael Kordosky
* [[Logic pulse widths and discriminator thresholds]]
197 68 Michael Kordosky
* [[WUT configuration]]
198 74 William Badgett
* [[Timing of ACnet TCLK Events]]
199 140 William Badgett
* The [[Teensy]] LAr ASIC controller's configuration
200 50 Michael Kordosky
201 138 Roberto Acciarri
* [[Punch Through counters voltages and rates ]]
202 138 Roberto Acciarri
203 102 Jason St. John
h1. Electronic Hardware Documentation
204 45 Michael Kordosky
205 51 Jason St. John
* Link to LArIAT eLog http://dbweb0.fnal.gov/ECL/lariat
206 51 Jason St. John
* [[LariatOnlineGit]] Accessing the LArIAT Online GIT repository
207 98 Brian Rebel
* [[Building LArIATOnline with CMake]]
208 44 Michael Kordosky
209 51 Jason St. John
* [[LArIAT TPC Readout Parameters]]
210 185 William Badgett
* [[LArASIC Preamp Documentation from BNL]]
211 51 Jason St. John
* [[LArIAT DAQ Commercial Products]] Technical Documentation and Firmware Files
212 101 William Badgett
* [[LArIAT CAEN Products]] Technical Documentation and Firmware Files
213 51 Jason St. John
* Test Beam Wire Chamber Sten Hensen's [[TDC Readout Documentation]]
214 89 William Badgett
* WUT Wave Union TDC: [[Jinyuan's TDC Documentation]]
215 51 Jason St. John
* [[v1495 notes]] Notes and working area for the V1495 and V2718
216 195 Johnny Ho
* [[A3818 PCI optical controller]] links
217 35 Michael Kordosky
218 1 William Badgett
* [[DAQ Configuration]] settings, parameters, starting a run
219 51 Jason St. John
* [[Raw Data Format and Readout Source code]]
220 100 John Freeman
* [[All things lariat-artdaq]] (UPDATED 11/5/14)
221 154 Jason St. John
* [[Interpreting Wire Chamber TDC Data]]
222 36 Michael Kordosky
223 54 Jason St. John
* [[LArIAT Test Stand]] Photographs
224 47 Michael Kordosky
225 72 Michael Kordosky
h1. Diagnostic and Control Software
226 72 Michael Kordosky
227 73 Michael Kordosky
_Test programs in the_ lariat-online/daq/src _directory_
228 73 Michael Kordosky
229 72 Michael Kordosky
* [[DumpDigitizerData]]
230 72 Michael Kordosky
* [[SummarizeDAQOutput]]
231 72 Michael Kordosky
* [[Reset1495]]
232 72 Michael Kordosky
* [[ScalarReadout]]
233 97 Pawel Kryczynski
* [[Data_quality_monitoring_module]]
234 72 Michael Kordosky
235 139 William Badgett
* CAEN's [[WaveDump]] utility
236 139 William Badgett
237 75 Jason St. John
h1. Examining the WC mini DAQ ASCII data
238 75 Jason St. John
239 75 Jason St. John
The Processor makes TTrees from the ASCII files saved by @mc7-daq.py@
240 82 Jason St. John
[[WC MiniDAQ Data Processor]]
241 75 Jason St. John
242 153 Jason St. John
h1. Data Files from the year 2013
243 76 Will Flanagan
244 85 William Badgett
Data files for various beam conditions can be found in the [[DataFiles]] page.
245 85 William Badgett
246 51 Jason St. John
h1. Meetings
247 51 Jason St. John
248 51 Jason St. John
* [[Connecting to LArIAT ReadyTalk]]
249 198 Johnny Ho
250 1 William Badgett
h1. Miscellaneous
251 198 Johnny Ho
252 216 Luke Batten
* The control room shifter computer (MCenter) can be logged into as ftbf_user@ftbflx18.fnal.gov after passing through lariat-gateway.fnal.gov
253 198 Johnny Ho
* [[Proxy using SSH tunnel]]