Wiki » History » Version 149
« Previous -
Version 149/332
(diff) -
Next » -
Current version
Jason St. John, 04/12/2015 12:24 PM
- Call the Main Control Room (x3721) at the start and at the end of shift. This is required, and pleasant.
- If the beam goes away for more than a few spills, look for Accelerator Alarms in ACNET (a default window). If the problem persists a few minutes, and you see nothing about it in the MCR elog, (or you just really want to find out more), call the MCR. They're friendly, though they may be super-busy.
- The LArIAT supercycle How DAQ operations relate to the supercycle
Shifter Stuff¶
- LArIAT Run 1 Shifter Instructions (March 2015)
Link summary¶
- LArIAT e-Log For making/ending access, starting/ending shifts.
- LArIAT Run 1 DAQ Instructions (March 2015)
- LArIAT Run Status Webpage
- LArIAT Online DQM (works with VPN or on-site only, for now)
- How to make DQM plots
- Synoptic
- Beam monitoring
- Accelerator Operations Elog
- MC7 WebCam
Important knowledge
Obsolete links¶
LArIAT Engineering Run (Aug 2014) How to Run the Lariat Data Acquisition(OBSOLETE)Shifter Instructions August 2014(Some obsolete information)How to make Lariat DAQ Plots(OBSOLETE)
Troubleshooting¶
Getting started- If you cannot ssh to FTBFLX machines: Get a kerberos ticket for yourself:
kinit <yourKerberosPrincipal>
, then ssh ftbf_user@ftbflx01 (or whichever machine...). - If your Kerberos username and password are good, but you can't log on to FTBFLX[NN] machines: Have someone who CAN log into those machines heck that your kerberos principal appears in
~ftbf_user/.k5login
in the LArIAT section.
- If the trigger crate has been power cycled and the V1495 is not emitting triggers: Reset1495
- If the wire chambers are acting strangely: mini-DAQ and telnet interface
- If the wire chamber system is skipping spill numbers, it may be a high trigger rate (> 30 k per spill). The wire chamber controller may still be reading out the hits from the last spill.
Hardware Connections and Configurations¶
- TPC Channel Mapping
- Non-TPC Detectors Naming and numbering in MC7
- Cable Patch Panel Spreadsheet
- Connections on the Control Room Patch Panel
- Logical inputs to the CAEN V1740
- Connections into the WUT TDC
- Connections into the V1751 Digitizer
- Connections in/out of the V1495 Trigger
- Logic pulse widths and discriminator thresholds
- WUT configuration
- Timing of ACnet TCLK Events
- The Teensy LAr ASIC controller's configuration
Electronic Hardware Documentation¶
- Link to LArIAT eLog http://dbweb0.fnal.gov/ECL/lariat
- LariatOnlineGit Accessing the LArIAT Online GIT repository
- Building LArIATOnline with CMake
- LArIAT TPC Readout Parameters
- LArIAT DAQ Commercial Products Technical Documentation and Firmware Files
- LArIAT CAEN Products Technical Documentation and Firmware Files
- Test Beam Wire Chamber Sten Hensen's TDC Readout Documentation
- WUT Wave Union TDC: Jinyuan's TDC Documentation
- v1495 notes Notes and working area for the V1495 and V2718
- DAQ Configuration settings, parameters, starting a run
- Raw Data Format and Readout Source code
- All things lariat-artdaq (UPDATED 11/5/14)
- LArIAT Test Stand Photographs
Diagnostic and Control Software¶
Test programs in the lariat-online/daq/src directory
- CAEN's WaveDump utility
Examining the WC mini DAQ ASCII data¶
The Processor makes TTrees from the ASCII files saved by mc7-daq.py
WC MiniDAQ Data Processor
Data Files¶
Data files for various beam conditions can be found in the DataFiles page.