Communicating with the wire chambers » History » Version 7

Jason St. John, 08/06/2014 02:23 PM

1 1 Michael Kordosky
h1. Communicating with the wire chambers
2 1 Michael Kordosky
3 2 Jason St. John
h2. Running the Wire Chamber Mini-DAQ
4 2 Jason St. John
5 6 Jason St. John
setup ftbf
6 3 Jason St. John
cd ~ftbf_user/experiments/mc7
7 3 Jason St. John
Look in instructions.txt
8 2 Jason St. John
9 7 Jason St. John
When you have a few seconds before a spill (in case you want to type a comment before you start the run)
10 3 Jason St. John
./daq-mc7.py
11 3 Jason St. John
12 4 Jason St. John
This daq fills one data file, appending each spill, until the user stops it.
13 3 Jason St. John
14 3 Jason St. John
h2. Looking at the data, Beam Study
15 3 Jason St. John
16 5 Jason St. John
ssh ftbflx01
17 3 Jason St. John
setup cern
18 3 Jason St. John
cd ~ftbf_user/experiments/mv7/BmStud
19 5 Jason St. John
20 5 Jason St. John
21 2 Jason St. John
22 1 Michael Kordosky
h2. How to do a hard reboot of the WC
23 1 Michael Kordosky
24 1 Michael Kordosky
If the wire chamber controller at ftbfwc02 starts refusing connections it may need a reboot:
25 1 Michael Kordosky
26 1 Michael Kordosky
* from a browser go to http://ftbf-pdu00.fnal.gov
27 1 Michael Kordosky
* User: admin   Password: <on the board in the CR>
28 1 Michael Kordosky
* Navigate to this screen:
29 1 Michael Kordosky
30 1 Michael Kordosky
!ftbfpdu00_control_screen.png!
31 1 Michael Kordosky
32 1 Michael Kordosky
* click on "Outlet 6" and then choose "Immediate Reboot" from the menu at the top
33 1 Michael Kordosky
* The state will change to "Off" but will be pending. Wait a little while and refresh the screen or log back in. The WC should be back on.