Project

General

Profile

How to use the online monitoring » History » Version 26

Flor de maria Blaszczyk, 07/29/2014 12:11 PM

1 4 Flor de maria Blaszczyk
{{toc}}
2 4 Flor de maria Blaszczyk
3 1 Flor de maria Blaszczyk
h1. How to use the online monitoring
4 1 Flor de maria Blaszczyk
5 8 Flor de maria Blaszczyk
The online-monitoring can be accessed from both off-site locations, though a web-browser, and on-site locations using either a web-browser or the Synoptic viewer (Java application). 
6 2 Flor de maria Blaszczyk
7 15 Flor de maria Blaszczyk
h2. 1) Opening the web-viewer or the java viewer application
8 1 Flor de maria Blaszczyk
9 8 Flor de maria Blaszczyk
h3. Outside Fermilab
10 8 Flor de maria Blaszczyk
11 14 Flor de maria Blaszczyk
If you are off-site, you will only be able to look at the displays. No settings are possible from outside Fermilab.
12 1 Flor de maria Blaszczyk
13 4 Flor de maria Blaszczyk
1) Open a browser and go to the "Synoptic":http://synoptic.fnal.gov/ website
14 2 Flor de maria Blaszczyk
15 6 Flor de maria Blaszczyk
2) Click on the LArIAT folder, this will expand the contents. Then click on the "Displays Main menu" link.
16 1 Flor de maria Blaszczyk
!synoptic_menu.png!
17 2 Flor de maria Blaszczyk
18 2 Flor de maria Blaszczyk
19 8 Flor de maria Blaszczyk
h3. In Fermilab
20 2 Flor de maria Blaszczyk
21 1 Flor de maria Blaszczyk
There are 2 possibilities, depending on whether you wish to only look at the displays or do settings / interact with the displays (i.e. zoom in, zoom out etc.)
22 1 Flor de maria Blaszczyk
23 9 Flor de maria Blaszczyk
1) If you only wish to look at the displays, please follow the procedure described in the previous section. Otherwise follow the next steps.
24 2 Flor de maria Blaszczyk
25 8 Flor de maria Blaszczyk
2) Get a Kerberos ticket, otherwise the viewer will shut down.
26 8 Flor de maria Blaszczyk
27 8 Flor de maria Blaszczyk
3) Open a browser and launch the viewer (Java required).
28 1 Flor de maria Blaszczyk
!synoptic_menu2.png!
29 9 Flor de maria Blaszczyk
30 11 Flor de maria Blaszczyk
4) Click on the button shown by the arrow to get started. 
31 1 Flor de maria Blaszczyk
!viewer_1.png!
32 12 Flor de maria Blaszczyk
33 12 Flor de maria Blaszczyk
_Note: If this is not the first time you are opening a viewer, you will have a pop-up window showing the latest displays used. You can either choose the display you'd like to look at from there or you can just close that window and start from the beginning._
34 9 Flor de maria Blaszczyk
35 1 Flor de maria Blaszczyk
5) Expand the LArIAT folder by clicking (double-clicking) on it and open the displays main menu.
36 10 Flor de maria Blaszczyk
!viewer_2.png! -> !viewer_3.png!
37 9 Flor de maria Blaszczyk
38 26 Flor de maria Blaszczyk
h3. From the FTBF MCenter Control Room computers (ftbflx10 and ftbflx11)
39 26 Flor de maria Blaszczyk
40 26 Flor de maria Blaszczyk
1) Open a console.
41 26 Flor de maria Blaszczyk
42 26 Flor de maria Blaszczyk
2) Go to /home/nfs/ftbf_user/acnet.
43 26 Flor de maria Blaszczyk
44 26 Flor de maria Blaszczyk
3) Run the launch_acnet program. This will get automatically a kerberos ticket with settings permissions and launch and acnet console.
45 26 Flor de maria Blaszczyk
46 26 Flor de maria Blaszczyk
4) Go to page D99 (either by opening the D menu and clicking twice then clicking on 99 Synoptic Viewer or just type D99 directly). This will launch the Synoptic viewer.
47 26 Flor de maria Blaszczyk
48 26 Flor de maria Blaszczyk
*Note: Do not open Synoptic Viewer through a web-browser since the application will have some issues in finding the kerberos ticket thus doing settings won't be possible*
49 26 Flor de maria Blaszczyk
50 26 Flor de maria Blaszczyk
51 15 Flor de maria Blaszczyk
h2. 2) The displays main menu
52 1 Flor de maria Blaszczyk
53 21 Flor de maria Blaszczyk
!main_menu.png!
54 21 Flor de maria Blaszczyk
55 22 Flor de maria Blaszczyk
This is the main menu. Click on the menu to open the display / control panel you would like to look at. 
56 22 Flor de maria Blaszczyk
57 13 Flor de maria Blaszczyk
*Note: All the displays have a button that allows you to go back to the main menu, generally at the bottom right corner of the display.*
58 13 Flor de maria Blaszczyk
59 15 Flor de maria Blaszczyk
h2. 3) Summary plots
60 13 Flor de maria Blaszczyk
61 13 Flor de maria Blaszczyk
Unless you need to change some setting, these are probably the displays you will need to look at most of the time.
62 13 Flor de maria Blaszczyk
 
63 15 Flor de maria Blaszczyk
h2. 4) A control display example
64 1 Flor de maria Blaszczyk
65 21 Flor de maria Blaszczyk
!ControlSample.png!
66 21 Flor de maria Blaszczyk
67 24 Flor de maria Blaszczyk
*Settings are disabled by default.* This means you can zoom in / out on the plots but cannot change any setting.
68 22 Flor de maria Blaszczyk
69 1 Flor de maria Blaszczyk
1) To enable settings, click on the button on the bottom right hand corner and select for how long you wish to enable the settings.
70 22 Flor de maria Blaszczyk
71 22 Flor de maria Blaszczyk
2) To turn on / off an power supply, click on the on / off button. A window will pop-up for confirmation. When the supply is on, the light should be green.
72 22 Flor de maria Blaszczyk
73 22 Flor de maria Blaszczyk
3) Turn on the regulate function (the light will turn green). This is to have an output voltage that matches the set voltage, otherwise there is a small offset.
74 22 Flor de maria Blaszczyk
75 22 Flor de maria Blaszczyk
4) Click on the button in the green frame "Set voltage" (in volts) next to the power supply you would like to set a voltage to. A window will pop up, enter the value including the "-" sign and validate. If you enter a positive value, nothing will happen. You will have to re-enter a value.
76 22 Flor de maria Blaszczyk
77 21 Flor de maria Blaszczyk
5) The selected supply readout voltage should indicate the new output voltage. Please wait until the reading stabilizes before changing to another value. This might take a few seconds.
78 22 Flor de maria Blaszczyk
79 23 Flor de maria Blaszczyk
Current can be readout in the bottom left hand side of the display. The top plot shows the voltage as a function of time, the bottom plot is the current as a function of time.
80 1 Flor de maria Blaszczyk
81 25 Flor de maria Blaszczyk
*Note: To power off a supply, please set the voltage to 0 first and then turn it off. Do not forget to turn it off!*
82 23 Flor de maria Blaszczyk
83 23 Flor de maria Blaszczyk
84 21 Flor de maria Blaszczyk
h2. 5) Closing / Restarting the displays (please read before closing any display!)
85 23 Flor de maria Blaszczyk
86 1 Flor de maria Blaszczyk
Should a display crash or should you wish to close it, just click on the top right hand corner red cross. Plots are reset when the display is closed so do not close a display unless it is really necessary.
87 1 Flor de maria Blaszczyk
88 24 Flor de maria Blaszczyk
h1. Troubleshooting
89 24 Flor de maria Blaszczyk
90 24 Flor de maria Blaszczyk
Because of some recent changes on the Java platform, you might have do to some tweaks to the Java security parameters. If you get an error that says that the application cannot be launched because it is from an unknown source / signature, please do the following:
91 24 Flor de maria Blaszczyk
92 24 Flor de maria Blaszczyk
1) Open the Java control panel. How to access it varies according to the OS (Google is your friend). You might have to launch it with admin privileges.
93 24 Flor de maria Blaszczyk
94 24 Flor de maria Blaszczyk
2) Select the security tab.
95 24 Flor de maria Blaszczyk
96 24 Flor de maria Blaszczyk
3) Drop the security to medium level.
97 24 Flor de maria Blaszczyk
98 24 Flor de maria Blaszczyk
4) Add the following links to the exceptions list:
99 24 Flor de maria Blaszczyk
http://synoptic.fnal.gov
100 24 Flor de maria Blaszczyk
http://www-bd.fnal.gov
101 24 Flor de maria Blaszczyk
102 24 Flor de maria Blaszczyk
5) Validate. You might have to restart the computer for this changes to take effect.
103 24 Flor de maria Blaszczyk
104 25 Flor de maria Blaszczyk
*Note: Make sure you type "http" and not "https". The latter will not work.*
105 17 Flor de maria Blaszczyk
106 17 Flor de maria Blaszczyk
h1. Contact
107 18 Flor de maria Blaszczyk
108 19 Flor de maria Blaszczyk
*LArIAT contact*: Flor de Maria Blaszczyk (Louisiana State University), fblaszczyk@phys.lsu.edu
109 17 Flor de maria Blaszczyk
_Need a new display? Don't understand something? Please let me know! All suggestions and comments are welcome._
110 18 Flor de maria Blaszczyk
111 1 Flor de maria Blaszczyk
*Synoptic support*: synoptic-support@fnal.gov