Description

Currently, artdaq XMLRPC commands accept a timeout parameter, which defaults to 45 seconds. DAQInterface has transition timeouts defined for the applications, but does not populate this parameter.

History

#1 Updated by Eric Flumerfelt 2 months ago

  • Status changed from New to Resolved

Fixes are on artdaq:bugfix/25538_I8ToIntFallback and artdaq-utilities-daqinterface:bugfix/25538_SendTimeoutParameter

#2 Updated by Gennadiy Lukhanin about 2 months ago

  • Status changed from Resolved to Reviewed

Both branches artdaq:bugfix/25538_I8ToIntFallback and artdaq-utilities-daqinterface:bugfix/25538_SendTimeoutParameter were tested on the SBN-ND cluster with one NEVIS TPC boardreader running in the fake mode. Runs 647 and 648 started OK and did not timeout after 45 secs.

#3 Updated by Eric Flumerfelt about 2 months ago

  • Target version set to artdaq v3_09_05
  • Status changed from Reviewed to Closed
  • Project changed from artdaq Utilities to artdaq

Also available in: Atom PDF