HWR resonance control pressure set button is broken

Added by Brian Chase 4 months ago. Updated 4 months ago.

Status:
Resolved
Priority:
High
Assignee:
Start date:
07/01/2020
Due date:
% Done:

100%

Estimated time:
Duration:

Description

HWR resonance control pressure set button is broken. This means we can't set the pressure set point. The card needs to be repaired and this work needs to fit around commissioning.
Talk with me about repairs.

History

#1 Updated by Daniel Klepec 4 months ago

  • % Done changed from 0 to 100
  • Status changed from New to Resolved

The set button doesn't seem to be broken. I took the card out and the button seemed to be jammed in the hole. I released it, and it responded fine. Philip later used the set button in operation and succeeded on the first attempt. When using the button, support the board with your finger while pressing the button. If any problem exists later, I removed a push button from another card and can replace it if necessary.