For some reason, recent commits in otsdaq have started to cause the following error:

17 Jan 2020 17:51:37.147 [139686750513344] FATAL root <> - Uncaught exception in main thread terminate called after throwing an instance of 'cet::coded_exception<fhicl::error, &fhicl::detail::translate[abi:cxx11]>'
  what():  ---- Type mismatch BEGIN

  Unsuccessful attempt to convert FHiCL parameter 'debugModules[0]' to type 'std::__cxx11::basic_string<char, std::char_traits<char>, std::allocator<char> >'.

  [Specific error:]
  bad any_cast

---- Type mismatch END

Investigating the versions of messagefacility currently in use shows that the debugModules configuration parameter is considered obsolete, and we should probably remove it from configureMessageFacility to avoid future issues.

History

#1 Updated by Eric Flumerfelt 8 months ago

  • Description updated (diff)

#2 Updated by Eric Flumerfelt 8 months ago

  • Status changed from New to Resolved

Resolved on artdaq-core:bugfix/23922_configureMessageFacility_removeDebugModules

#3 Updated by Ron Rechenmacher 8 months ago

  • Status changed from Resolved to Reviewed

code review; created e17:s67 demo including artdaq_mfextensions; ran demo w/ and w/o artdaq-core:bugfix branch to see that msgviewer receives approx. same msgs.

#4 Updated by Eric Flumerfelt 7 months ago

  • Target version set to artdaq-core v3_05_10
  • Status changed from Reviewed to Closed


Also available in: Atom PDF