SamplingInput job throws exception when using drop commands

Added by Richard Bonventre 12 months ago. Updated 12 months ago.

Status:
Closed
Priority:
Normal
Assignee:
Target version:
Start date:
07/16/2019
Due date:
% Done:

100%

Estimated time:
Scope:
Internal
Experiment:
Mu2e
Duration:

Description

Failure mode is error:

---- EventProcessorFailure BEGIN
EventProcessor: an exception occurred during current event processing
---- Configuration BEGIN
The process name test was previously used on these products.
Please modify the configuration file to use a distinct process name.
---- Configuration END
---- EventProcessorFailure END

History

#1 Updated by Kyle Knoepfel 12 months ago

  • Scope deleted (Internal)
  • Subject changed from Some job setups cause errors when trying to use more than one output stream to SamplingInput job throws exception when using drop commands
  • Project changed from cet-is to art_root_io
  • SSI Package deleted (art)

#2 Updated by Kyle Knoepfel 12 months ago

  • % Done changed from 0 to 100
  • Assignee set to Kyle Knoepfel
  • Status changed from New to Resolved

This bug has been fixed with commit art_root_io:ce604b2.

#3 Updated by Kyle Knoepfel 12 months ago

  • Target version set to 3.03.01

#4 Updated by Kyle Knoepfel 12 months ago

  • Status changed from Resolved to Closed

#5 Updated by Kyle Knoepfel 12 months ago

  • Target version changed from 3.03.01 to 1.01.03