Project

General

Profile

Task #20522

Milestone #20350: IOTA BPM deployment

Milestone #19607: IOTA ACNET Interface

ACNET device for Arming IOTA BPMs

Added by John Diamond 10 months ago. Updated 9 months ago.

Status:
Assigned
Priority:
Normal
Start date:
08/03/2018
Due date:
% Done:

90%

Estimated time:
Spent time:
Duration:

Description

A ACNET device with a control property that operators can use to manually arm a measurement.

History

#1 Updated by Elliott McCrory 9 months ago

  • % Done changed from 0 to 10

I have implemented these devices for implementing the arming, and all the other things

Description Name ACNET Default SSDN
The measure index to use for the arm armIndex N:IBPMMEAS 0 0AB8/0/0/0
The turn number to use turn N:IBPMTURN 0 0BB8/0/0/0
Number to average nAvg N:IBPMAVG 0 0CB8/0/0/0
Number of orbits nOrbits N:IBPMORBITS 100 0DB8/0/0/0
Number to skip nSkip N:IBPMSKIP 0 0EB8/0/0/0

#2 Updated by Elliott McCrory 9 months ago

  • % Done changed from 10 to 60

Here are the digital control bits in N:IBPSTATD (taking some liberties to rename the old ones):

Bit Posn Num Short Name Description
00000001 0 Start Start local daemon process
00000002 1 Stop Stop local daemon process
00000004 2 Restart Restart local daemon process
00000008 3 EnableSM Enable Front End State Machine
00000010 4 DisableSM Disable Front End State machine
00000020 5 ARM Send an ARM command
00000040 6 ReadRaw Perform a RAW readout
00000080 7 ReadTBT Perform a TBT readout
00000100 8 ReadCO Perform a Closed Orbit readout
00000200 9 ReadFO Perform a Flash Orbit readout
00000400 10 ReadFT Perform a Flash Turn readout

#3 Updated by Elliott McCrory 9 months ago

  • % Done changed from 60 to 90


Also available in: Atom PDF