Bug #20330
Issue du jour #2 at protoDUNE, 17-Jul-2018: the DAQ system only supports 0.7 Hz
Status:
Resolved
Priority:
High
Assignee:
-
Category:
-
Target version:
-
Start date:
07/17/2018
Due date:
% Done:
0%
Estimated time:
Experiment:
-
Co-Assignees:
Description
3.0 Hz is what Wes reported as a necessary rate, for now
History
#1 Updated by Kurt Biery over 2 years ago
- Priority changed from Normal to High
#2 Updated by Wesley Ketchum over 2 years ago
Getting routing master working has helped bring us to ~3 Hz stable running I believe. Still need some work here though. Current lines of work are:
(1) modify sending buffers on BoardReaders to avoid timeouts/blocking TCP calls
(2) better balancing on sending tokens to RoutingMaster
#3 Updated by Kurt Biery over 2 years ago
- Status changed from New to Resolved