Description

The dcm-3-01-01:6 FEB temperature switches between 0C and ~36C, which causes an alarm every time the temperature is 0C because it is lower than the alarm threshold (15C).

History

#1 Updated by Martin Frank almost 9 years ago

Logbook entry 9741 shows a plot of the oscillating FEB temperature.

#2 Updated by Martin Frank almost 9 years ago

  • Status changed from New to Resolved

This has been resolved (see Logbook 9896) by swapping out the FEB.