Project

General

Profile

Bug #17416

Conversion of hex values to decimal on database check-in

Added by Martin Haigh about 2 years ago. Updated about 1 year ago.

Status:
Resolved
Priority:
High
Category:
artdaq-database
Target version:
-
Start date:
08/09/2017
Due date:
% Done:

0%

Estimated time:
Experiment:
DUNE
Co-Assignees:
Duration:

Description

When importing FHiCL to the database, integers in hex representation are converted to decimal, and this conversion is not reverted on re-export (presumably the information on the representation used has been lost). FHiCL for device configuration contains literal hardware register values which are difficult to read/write in decimal, and this represents a major maintenance issue for run configurations.


Related issues

Related to artdaq Utilities - Bug #17425: FHiCL numerical parameters truncated by DB!Resolved08/10/2017

History

#1 Updated by Gennadiy Lukhanin about 2 years ago

  • Related to Bug #17425: FHiCL numerical parameters truncated by DB! added

#2 Updated by Gennadiy Lukhanin about 1 year ago

  • Status changed from New to Resolved

Fixed in the version v1_04_46 of artdaq_database.



Also available in: Atom PDF