Configure a cycle device that measures each micro-bunch injection for g-2 operation.

History

#1 Updated by John Diamond over 3 years ago

Our last e-mail to the Muon department suggested that the device be called R:T703Ix (where x comes from the recycler reset TCLK event).

#2 Updated by John Diamond over 3 years ago

  • Subject changed from Configure a cycle device for R:TOR753 g-2 operation to Configure a cycle device for R:TOR703 g-2 operation

#3 Updated by John Diamond over 3 years ago

  • Status changed from New to Resolved
  • % Done changed from 0 to 100

Configured a cycle device with 8 events called R:T703E9 and an injection cycle device triggered on the $F6 called R:T703I9.

Found that the CycleDevice class has a hard-limit of 6 samples. Increased this to 32.

Unfortunately the cycle device support as it stands has no way of supporting two different samples with the same TCLK event like the g-2 transfers are structured. We will need to come up with a way to support the second group of 8 transfers. I will create another ticket for this.

#4 Updated by John Diamond over 3 years ago

See #16050 for supporting the second group of 8 transfers.