#1 Updated by John Diamond about 4 years ago
Scale factors from Ning:
PXIE Ring Pickup Scaling Factors - 11/3/2016 On front end code: 1. M01EPC (Average Current mA) and M01EPA (moving average of M01EPC): Current_Reading = C1 * ( C3 ^ ( C2 * RAW_CURRENT ) ) + C4 Attention: Set D80 Scaling to 1. 2. M01EPI (Intensity E10): INT_Reading = C5 * Current_Reading * GW + C6 Attention: Set D80 Scaling to 1. 3. Intensity Threshold Settings, common unit E10(?) ( P:MPRLT , P:MPRUT ): I_THR = ( log_base_C3( ( ( Threshold_Setting - C6) / ( GW * C5 ) - C4 ) / C1 ) ) * GW / C2 Attention: Set D80 Scaling to 1. RAW_CURRENT: Raw Reading of "Intensity Reading Register" * GW GW: Raw Reading of "Chopper Gate Width register" I_THR: Register Value for ( upper and lower ) thresholds. Threshold_Setting: D80 Setting for Upper and Lower Thresholds For M01EPC, M01EPA, M01EPI, MPRLT, MPRUT: C1 = -0.83655 C2 = 0.0003773625 C3 = 1.7 C4 = 0.092139 C5 = 0.004997418 C6 = 1.445763 For M02EPC, M02EPA, M02EPI, (Lower Threshold Device Name?), (Upper Threshold Device Name?): C1 = -0.939618 C2 = 0.0003773625 C3 = 1.7 C4 = 0.139714 C5 = 0.049947 C6 = 2.042
#2 Updated by John Diamond about 4 years ago
- Status changed from New to Work in progress
- % Done changed from 0 to 90
Done & ready for testing out at PXIE.
#3 Updated by John Diamond about 4 years ago
PXIE actually wanted the ring pickup thresholds scaled to current, not intensity. Ning came up with new formulas for doing the scaling and revised the scaling factors -
PXIE Ring Pickup Scaling Factors - 11/3/2016 On front end code: 1. M01EPC (Average Current mA) and M01EPA (moving average of M01EPC): Current_Reading = C1 * ( C3 ^ ( C2 * RAW_CURRENT ) ) + C4 Attention: Set D80 Scaling to 1. 2. M01EPI (Intensity E10): INT_Reading = C5 * Current_Reading * GW + C6 Attention: Set D80 Scaling to 1. 3. Intensity Threshold Settings, common unit E10 ( P:MPRLT , P:MPRUT ): I_THR = ( log_base_C3( ( ( Threshold_Setting - C6) / ( GW * C5 ) - C4 ) / C1 ) ) * GW / C2 Attention: Set D80 Scaling to 1. 3a. Current Threshold Settings, common unit mA ( assign P:MPRLT , P:MPRUT to use this): C_THR = log_base_C3( ( Current_Reading - C4 ) / C1 ) * GW / C2 Attention: Set D80 Scaling to 1. RAW_CURRENT: Raw Reading of "Intensity Reading Register" * GW GW: Raw Reading of "Chopper Gate Width register" I_THR: Register Value for ( upper and lower ) thresholds. C_THR: Register Value for ( upper and lower ) Current thresholds. Threshold_Setting: D80 Setting for Upper and Lower Thresholds For M01EPC, M01EPA, M01EPI, MPRLT, MPRUT: C1 = -0.83655 C2 = 0.0003773625 C3 = 1.7 C4 = 0.092139 C5 = 0.004997418 C6 = 1.445763 For M02EPC, M02EPA, M02EPI, MPR2LT, MPR2UT: C1 = -0.939618 C2 = 0.0003773625 C3 = 1.7 C4 = 0.139714 C5 = 0.049947 C6 = 2.042