Project

General

Profile

Task #11858

Commission node at MI-60S for RF spill monitor

Added by John Diamond almost 5 years ago. Updated almost 5 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Start date:
03/01/2016
Due date:
% Done:

100%

Estimated time:
Spent time:
Duration:

History

#1 Updated by John Diamond almost 5 years ago

Let's call the node sbpm6s.

#2 Updated by John Diamond almost 5 years ago

  • % Done changed from 0 to 20

Submitted a connection request to the networking group. Service ticket REQ000000263850.

#3 Updated by John Diamond almost 5 years ago

  • % Done changed from 20 to 40

From Steve:

the hookup at MI60 South by rack MI60204 is ready. There is a cable hanging in front of the rack with some extra 
length. The new IP for the device you renamed to "sbpm6s" is 131.225.117.178 with a mask of 255.255.255.0 and a
gateway of 131.225.117.200.

#4 Updated by John Diamond almost 5 years ago

boot device          : dc0
processor number     : 0
host name            : fecode-bd
file name            : vxworks_boot/kernel/mv2400/v5_5/vxWorks
inet on ethernet (e) : 131.225.117.178:ffffff00
inet on backplane (b):
host inet (h)        : 131.225.121.145
gateway inet (g)     : 131.225.117.200
user (u)             : vxworks_boot
ftp password (pw) (blank = use rsh):
flags (f)            : 0x0
target name (tn)     : sbpm6s
startup script (s)   : vxworks_boot/fe/sbpm6s/sbpm6sstartup

#5 Updated by John Diamond almost 5 years ago

  • % Done changed from 40 to 60

Created node area and installed devvmebpm.out and sbpm6sstartup.
Went out to MI-60 and found the node located behind the racks by MECAR, on a stand.
Hooked up the serial cable and configured the IP address above.
Had to ssh vxworks_boot@chablis and addhost to register the new node name with fecode-bd.
Had to switch the kernel to the 512MB tbpm version (see configuration below).
E-mailed Glenn Johnson asking for a new ACNET node name and ID.

Current node setup:

'.' = clear field;  '-' = go to previous field;  ^D = quit

boot device          : dc0
processor number     : 0
host name            : fecode-bd
file name            : vxworks_boot/kernel/mv2400-512MB/vxWorks-tbpm
inet on ethernet (e) : 131.225.117.178:ffffff00
inet on backplane (b):
host inet (h)        : 131.225.121.145
gateway inet (g)     : 131.225.117.200
user (u)             : vxworks_boot
ftp password (pw) (blank = use rsh):
flags (f)            : 0x0
target name (tn)     : sbpm6s
startup script (s)   : vxworks_boot/fe/sbpm6s/sbpm6sstartup
other (o)            :

Startup script is halted at the top, before MOOC is start until ACNET node is registered.

#6 Updated by John Diamond almost 5 years ago

  • Status changed from Assigned to Closed
  • % Done changed from 60 to 100

Received ACNET node ID from Glenn. Final boot config is:

boot device          : dc0
processor number     : 0
host name            : fecode-bd
file name            : vxworks_boot/kernel/mv2400-512MB/vxWorks-tbpm
inet on ethernet (e) : 131.225.117.178:ffffff00
inet on backplane (b):
host inet (h)        : 131.225.121.145
gateway inet (g)     : 131.225.117.200
user (u)             : vxworks_boot
ftp password (pw) (blank = use rsh):
flags (f)            : 0x0
target name (tn)     : sbpm6s_0xc40
startup script (s)   : vxworks_boot/fe/sbpm6s/sbpm6sstartup
other (o)            :

Created the following devices for the RF Spill monitor at 714:
  • I:RFS714
  • I:RFI714

Also available in: Atom PDF