#1 Updated by Jonathan Eisch about 4 years ago

  • % Done changed from 0 to 80

Amplitude and phase measured from 1 to 240MHz for BNC-T, pickoff/splitter prototype and UC-Irvine provided pickoff with BNC-T splitter.

Amplitude is roughly constant. Plots to come.

#2 Updated by Jonathan Eisch almost 4 years ago

  • Status changed from Assigned to Closed
  • % Done changed from 80 to 100

Had cross-talk issue. Fixed with proper grounding.